Specifications
SER-7000 Program Manual P-Mode Programming
109
Cash Drawer Options
CASH DRAWER OPTIONS
1. SALES WITH DRAWER OPEN Y
2. C-I-D AMOUNT LIMIT 00000.00
3. OPEN DRAWER DURING X-RPT N
4. OPEN DRAWER DURING Z-RPT N
5. ACTIVATE OPEN DRAWER ALARM N
6. OPEN DRAWER ALARM TIME 030
ESC Y/N ENTER PAGE UP/DN
1. Select CASH
DRAWER OPTIONS
from the SYSTEM
OPTION
PROGRAMMING
screen. The cash
drawer options
display with the first
option field selected.
(There is only one
page of cash drawer
options.)
2. Select fields and
change information in
the same manner as
described for general
options.
Cash Drawer Options Program Notes
# FIELD Notes
1 SALES WITH DRAWER OPEN
Choose Y to force the drawer to be closed
before registrations are allowed.
2 C-I-D AMOUNT LIMIT
Set the maximum amount of cash in drawer
before a error tone and message display. The
error can be cleared and continued sales are
allowed, however the warning continues to
sound at the completion of each transaction,
until cash is removed from the drawer. Set
the amount to 0 to disable the cash in drawer
limit warning.
3 OPEN DRAWER DURING X-
RPT
Choose Y to open the drawer at the
completion of any X report.
4 OPEN DRAWER DURING Z-
RPT
Choose Y to open the drawer at the
completion of any Z report.
5 ACTIVATE OPEN DRAWER
ALARM
If Y, an error tone sounds when the cash
drawer remains open the length of time
specified in option #6 below.
6 OPEN DRAWER ALARM
TIME
Enter length of time the drawer may be open
(in seconds) before the open drawer alarm
sounds.