Specifications

SAM4S NR-500 Series Manual Program Mode Programming 151
Option Entry Description
OPEN DRAWER ON
POST TENDER
Y or N
If you enable post tendering, select N to not open
the cash drawer after the second tender.
GLOBAL ENTRY
LIMIT
(0-14)
0-14 Enter a digit to determine the number of numeric
digits that can be entered for any register function.
Enter 0 for no limit.
ALLOW
MULPTIPLE
RECEIPT
Y or N
Set to Y if you wish to issue more than one copy of
a transaction receipt.
DEACTIVATE SPLIT
PRICING
Y or N
If N, both multiplication and split pricing
calculations can be done with the X/TIME key.
If Y, only multiplication can be done with the
X/TIME key.
ALLOW DIRECT
MULTIPLY
Y or N
If Y, you can multiply preset items by simply
entering the quantity, then pressing the preset PLU
key.
DIRECT MULTIPLY
OVER ONE DIGIT
Y or N If you allow direct multiplication of a preset PLU,
you can allow only single digit multiplication or
multiplication by more than one digit.
TRIPLE
MULTIPLICATION
Y or N
DISPLAY ADD
PRICE OF LINKED
ITEMS
Y or N When Y, the customer display shows a total of the
item and linked item. For example, if PLU is
1.00 and is linked to PLU2 which is 0.25, the
customer display will show 1.25.
PROMPT FOR
PRICE IF
PRICE=0.00
Y or N
COMPULSORY
SUBT.BEFORE
TENDER
Y or N
Select Y if you want to force the operator to use
the SUBTOTAL function before tendering.
ENABLE NOT
FOUND PLU
Y or N Select Y to allow the operator to enter PLU prices
and other data when the entered PLU number is not
found in the PLU file.
NOT FOUND PLU
TYPE
QUICK
FULL
NEGATIVE SALE
MGR ONLY
Y or N
Select Y if you wish to control negative
transactions (when cash is removed from the
drawer). When selected mode position must be in
the Manager mode to finalize the transaction.