Specifications

SAM4S NR-500 Series Manual Service Mode Programming 111
To Save Reports
1. Insert the USB memory in the registers USB port.
2. Move to the SERVICE MODE.
3. From the Service Mode menu, select “7.PROGRAM BACKUP”.
4. From the PROGRAM menu, select “2.USB”.
5. From the USB menu select3.REPORT SAVE.
6. The register will display confirmation of the successful restore. If the save is
unsuccessful, the register will print out an error message.
Load/Save Receipt Images
You can load a preamble and postamble image for your receipt or soft guest check.
Before loading, the images must be converted by the PC Utility to .img format. After
conversion, they can be loaded directly by connecting a PC to the NR-500 Series or by
copying the images to a USB memory and loading (or saving the image) using the USB
utility program described here.
Note that after loading the images, you must set LOGO (Print preamble image /
Print postamble image)” of the “Options Programming” in the Program Mode
Programming” to activate the image printing.
Preparing a Graphic Logo Bitmap for an NR-500 Series
See page on 102 for detail.