Specifications

ER-650/650R Program Mode Programming 209
WASTE
1. Press the WASTE key to view the waste function key options:
WASTE PROG.
DESC : WASTE
KEY HALO 0.00
(0 : NO LIMIT)
KEY DISABLE N
UNDER MGR CONTROL N
COMPULSORY VALID N
2. Press ENTER from the last field to return to the FUNCTION KEY
PROGRAM screen, or press ESC at any time to return to the FUNCTION
KEY PROGRAM screen without saving changes.
WASTE Key Program Notes
Option Entry Description
DESC Alpha
numeric
12 character
You can program a descriptor. The default descriptor is WASTE.
HALO 7 digit amount You can limit errors by setting the maximum amount that can be
used with this function. "0" means that there is no entry limit.
KEY DISABLE Y or N
Select Y to disable this function.
UNDER MGR
CONTROL
Y or N
Select Y if you do not want the operator use this function in
REGISTER mode. When selected, the function is allowed only
in the X control lock position.
COMPULSORY
VALIDATION
Y or N
Choose Y to enforce validation if an optional printer with validation
capability is connected to an RS-232C port.