Specifications

ER-650/650R Program Mode Programming 177
CHECK Key Program Notes
Option Entry Description
DESC Alpha numeric
12 character
You can program a descriptor. The default descriptor is CHECK.
HALO 7 digit amount You can limit errors by setting the maximum amount that can be
tendered. "0" means that there is no entry limit.
AMOUNT TEND
COMP.
Y or N
Select Y if you want to force the operator to enter the tendered
amount and let the register calculate the change.
OVER/UNDER
TENDER IN MGR
CONTROL
Y or N
Select Y if you do not want the operator to tender more than the
amount of the sale and issue change. When selected, over
tendering is allowed only in the X control lock position.
DISABLE UNDER
TEND.
Y or N
Select Y if you do not want the operator to tender less than the
amount of the sale.
DOES DRAWER
OPEN
Y or N
Select N if you do not want the drawer to open with this key.
EXEMPT TAX 1
EXEMPT TAX 2
EXEMPT TAX 3
EXEMPT TAX 4
Y or N
Select Y to exempt the appropriate tax automatically when
finalized with this key.
COMPULSORY
CHECK
ENDORSEMENT
Y or N
Choose Y to enforce check endorsement if an optional printer with
endorsement capability is connected to an RS-232C port.
COMPULSORY
VALIDATION
Y or N
Choose Y to enforce validation if an optional printer with
validation capability is connected to an RS-232C port.