User's Manual
Table Of Contents
- GENERAL
- 1 About these Operating Instructions
- 2 Safety Precautions
- 3 NACOS Platinum System Description
- 4 Multi Function Display
- 5 NACOS Platinum Graphical User Interface
- QUICK START GUIDE
- MAIN APPLICATIONS
- RADAR
- 1 General Information
- 1.1 RADAR Safety
- 1.2 Current IHO Standards / Regulatory Approvals
- 1.3 System Structure and Installation
- 1.4 Basics / Evaluation of the RADAR Video
- 1.4.1 Basics of the Evaluation of RADAR Video in Platinum Series
- 1.4.2 Achievable RADAR Range
- 1.4.3 Distortions of the RADAR Video
- 1.4.4 Undesirable Echo Displays and Effects
- 1.4.5 RADAR Setting for the Display of Racon Codes
- 1.4.6 RADAR Settings for Target Enhancer Detection
- 1.4.7 RADAR Setting for SART Detection (X-Band only)
- 1.4.8 Transmission formats
- 1.5 Basic setting of the RADAR Video
- 1.6 RADAR Accuracy
- 2 The RADAR Keyboard
- 3 An Overview of the Screen
- 4 RADAR Application Area
- 5 RADAR Sidebar - Permanent Area
- 6 RADAR Sidebar - Non-Permanent Area
- 7 Target Handling
- 7.1 Overview
- 7.2 Manual Target Acquisition
- 7.3 Manual Target Selection
- 7.4 Automatic Target Acquisition
- 7.5 Settings for Dangerous Targets
- 7.6 Settings for Acquisition/Guard Zones
- 7.7 Target Fusion
- 7.8 Deletion and Loss of Targets
- 7.9 Critical Target
- 7.10 Target List
- 7.11 Target Display
- 7.12 Trial Manoeuvre
- 7.13 Reference Target Tracking
- 7.14 ARPA Training
- 7.15 ARPA Malfunctions
- 7.16 AIS Malfunctions
- 8 User Symbols
- 9 CHARTRADAR (optional)
- 9.1 Overview
- 9.2 Basic Adjustments
- 9.3 Selecting the Objects to be Displayed in the Vector Chart
- 9.3.1 Overview
- 9.3.2 Categories of Display Groups
- 9.3.3 Select a Category
- 9.3.4 Select the Primary Chart Information Set (PCIS)
- 9.3.5 Indication of Category in the Status Line
- 9.3.6 Defining the Symbol Presentation
- 9.3.7 Setting the Display of Text Labels
- 9.3.8 Switch on Additional Information
- 9.3.9 Switch on Conditionally Displayed Features
- 9.4 CHARTRADAR Application Area
- 9.5 Application Area Context Menu
- 9.6 Setting the Depths Lines to be Displayed in the Vector Chart
- 9.7 Setting the Own Ship’s Draft
- 9.8 Activating the Chart Monitoring
- 9.9 Setting the Look-Ahead Sector
- 9.10 Chart Maintenance
- 9.11 Main Differences between CHARTRADAR and Full ECDISPILOT
- 1 General Information
- VOYAGE PLANNING AND MONITORING
- 1 Voyage Planning
- 1.1 Generation of Routes
- 1.1.1 General Information about Pre-planned Tracks
- 1.1.2 Generation, Handling and Administration of the Routes
- 1.1.3 Route Display Settings
- 1.1.4 Route Editing - Graphical
- 1.1.5 Route Editing - Text Mode
- 1.1.6 Details of the Waypoint Data
- 1.1.7 Checking of Routes
- 1.1.8 Completing the Generation of the Route
- 1.1.9 Import / Export Routes
- 1.1 Generation of Routes
- 2 Chart and Route Monitoring
- 1 Voyage Planning
- CONNING
- SENSORS
- OPTIONAL APPLICATIONS
- MAINTENANCE
- 1 Performance Monitor
- 2 Data Maintenance of the Electronic Charts
- 2.1 General
- 2.2 Starting Chart Maintenance
- 2.3 Chart Maintenance Application Area
- 2.4 Update of Charts from Media
- 2.5 Messages during Chart Update
- 2.6 Display Charts which are on a Media or a MFD (workstation)
- 2.7 Maintenance of Charts on your MFD (workstation)
- 2.8 Display Expander
- 2.9 Backup/Restore of Map Data
- 3 Manual ENC Update Editor
- 4 Hardware Maintenance
- 5 SW Version and Updates
- ALARMS
- LISTS AND INDEXES
- DOCUMENT HISTORY
ED 3100 G 140 / 04 (2011-11)
Operating Instructions
I-2 Safety Precautions
I General.fm / 10.11.11
I-15
NACOS Platinum
2.2 Meaning of Safety Signs
The operating instructions use the following safety signs which you will also find on equipment. Their
meaning is described shortly in order to give you an idea of the importance and the specific aspects to
be aware of.
HIGH VOLTAGE!
In case that the equipment is in use, dangerous voltages are present. Touching
live parts of devices energised with these voltages will result severe injuries or
even death. Appropriate actions must be taken. Before starting to work, observe
the following safety rules:
1. Switch off the equipment, disconnect the equipment from the mains
supply.
2. Take precautions against inadvertent re-connection.
3. To verify that circuits are dead and no voltage is present perform the
appropriate measurements.
4. Ground and short-circuit.
5. Cover live parts in the proximity or otherwise protect them against
touching.
The dangerous voltages are no longer present.
Voltage may only be applied to components being worked on when this is
expressly prescribed (e.g. during troubleshooting). Mains switches are live even
when the equipment is switched off. During work always observe the relevant
regulations for the prevention of accidents, e.g. German VBG 4, or EN 292. Only
use suitable, intact tools and measuring instruments!
DANGER! WORK IN PROGRESS! DO NOT SWITCH!
The switch(es) marked with this sign must never be operated.
Severe injuries or even death can occur as consequence of disregard.
The sign will have amendments like the name of the person who has marked the
switch(es) and time/date of mounting of the sign.
Only the person stated on the sign may remove the sign and operate the
switch(es).
TURNING DEVICES!
Marked devices or devices in the vicinity of this sign may start turning automati-
cally if the equipment is in use. Always switch off the respective equipment or
drives of the devices. Take precautions to prevent inadvertent reactivation of the
devices before you start to work on the devices.