User's Manual

Table Of Contents
AIS 3410, Electronics Unit
ED3047G842 / 01 (2009-08)
Technical Manual
6 Repair/Maintenance
6.1 Trouble Shooting
t_ue_e07.fm / 27.08.09
51
Fig. 6-2 Protocol Radar TxD
If the AIS voyage data is modified or safety related messages are sent, the protocol must show tele-
grams corresponding to the telegrams in Figure 6-2. If there is no communication on the interface,
the Analog Interface is defective or has a wrong software version (The software version must be F
or newer. To check the software version, use the Telemonitoring Data menu of the System Main
-
tenance manager. The line for the Analog Interface must look as follows: SIR10T GE3044P207 F)
or the configuration of the radar is faulty. See the Technical Manual of the radar for further informa
-
tion.
NOTE:
If a ship’s sensor is connected to the interface which has been used for the test, it must be made
sure, that all modifications of the parameterization of this interface that were necessary for the test
are cancelled.
Test of the AIS 3410 Output
1. Power Down the system
2. Connect the AIS Primary Display Port TB7 and TB8 additionally to an indicator serial interface (TB1)
of the radar. If there is a free input, this one should be used. If all inputs are used, one of them must
be disconnected.
Figure 6-1 shows the connection to the serial interface No. 4 as an example.
$PSAEAISALV*07
$RAVSD,69,12.0,0,BREMEN,142000.00,06,11,7,0*67
$PSAEAISALV*07
$PSAEAISALV*07
$PSAEAISALV*07
$PSAEAISALV*07
!RABBM,2,1,0,0,14,7B?E>49>7P<1DrkjriqfknhP>P<?>rihpripfinhPGPD9=5r>?FPimPinr,0*6E
!RABBM,2,2,0,0,14,ipPED3P31<<C97>rC1=P>1=5r=He=1B9>5PD5CDP==C9rjiijhoonh,0*79
$PSAEAISALV*07
$PSAEAISALV*07
$PSAEAISALV*07
$PSAEAISALV*07
Alive message, sent every 15 seconds
Voyage Data has been
modified at the Indicator.
Safety related messages
have been sent.