User's Manual
Table Of Contents
- List of Contents
- List of Figures
- List of Abbreviations
- 1 General
- 2 Overview
- 2.1 Compatibility with Other Systems
- 2.2 AIS 3410 in RADARPILOT 1000/1100 Systems
- 2.3 AIS 3410 in 1000/1100 Series Systems (NACOS xx-4 and xx-5)
- 2.4 AIS 3410 in CHARTPILOT Stand-alone Systems
- 2.5 AIS 3410 in NACOS xx-3 Systems (Radar 9xxx and CHARTPILOT)
- 2.6 AIS 3410 in Radar 9xxx Systems with RADARPILOT 1000/1100
- 2.7 AIS 3410 in Radar 9xxx Systems
- 2.8 Housing of the 3410 Electronics Unit
- 2.9 Replacement of AIS Electronics Unit
- 2.10 Media Converter Installation (necessary for ships with BNC LAN networks)
- 3 Installation Recommendations
- 3.1 General Recommendations
- 3.2 Specific Recommendations
- 3.2.1 Recommendations Concerning AIS Systems
- 3.2.2 Recommendations Concerning the Installation of the Electronics Unit
- 3.2.3 Recommendations Concerning the Installation of the Antennas
- 3.2.4 Recommendations Concerning Redundancy
- 3.2.5 Recommendations Concerning the Connection of a (D)GPS to AIS 3410
- 3.2.6 Emergency Power Source
- 3.2.7 Pilot Port, Connector/Cable Kits
- 3.2.8 Recommendations Concerning AIS Stand-alone with Radar 9xxx / NACOS xx-2/-3
- 3.2.9 Recommendations Concerning the Connection to a Radar 1000/1100 Series System
- 3.2.10 Recommendations Concerning the Connection to a Radar 1100 Series System
- 4 Functional Description
- 4.1 Block Diagram
- 4.2 Termination
- 4.3 Description of the Components
- 4.3.1 AIS 3410 Electronics Unit
- 4.3.1.1 Interfaces
- 4.3.1.2 Internal Connectors
- 4.3.1.3 Supported Sensor Input Sentences
- 4.3.1.4 Supported Sentences for the AIS Primary Display Port and the Pilot Port
- 4.3.1.5 Supported Sentences for the Long Range Port
- 4.3.1.6 Supported Sentences for the Internal Position Sensor
- 4.3.1.7 IEC 61162 -1/-2 Interfaces, Electrical Characteristics
- 4.3.1.8 Example for the Interconnection
- 4.3.2 VHF Antenna
- 4.3.3 GPS Antenna
- 4.3.4 Pilot Port
- 4.3.1 AIS 3410 Electronics Unit
- 5 Setting-to-Work/Configuration
- 6 Repair/Maintenance
- 7 Technical Data
- 8 Fault Code List
- 9 Cabling Documents
- 10 Outline Drawings
- Notes
AIS 3410, Electronics Unit
ED3047G842 / 01 (2009-08)
Technical Manual
3 Installation Recommendations
3.2 Specific Recommendations
t_ue_e03.fm / 27.08.09
28
3.2.4 Recommendations Concerning Redundancy
If possible, the Electronics Unit should be supplied with the ship’s sensor data from two different sources,
e.g. in a dual installation with RADARPILOT 1000 or 1100 the AIS can be supplied with sensor data from
both radars.
NACOS xx-3 only:
If two Ship’s Interfaces are existing because of redundancy purposes, the ship’s sensor output(s) of both
Ship’s Interfaces must be connected to the AIS Electronics Unit.
3.2.5 Recommendations Concerning the Connection of a (D)GPS to AIS 3410
For an AIS stand-alone installation with the connection of an external (D)GPS position sensor, the
following prerequisites must be fulfilled:
NMEA Version
NMEA version 2.01 edition 04/1994 or newer is required. In addition to this, the optional checksum is
required. The AIS requires status information to check the data integrity.
All NMEA versions lower than 2.01 are not allowed for the use with AIS. To verify, that the NMEA version
is 2.01 or higher, check the settings of the GPS sensor.
Data Telegrams
For all NMEA versions lower than 2.3 the GGA message must be transmitted. Only the GGA message
transmits the information, that the differential mode is activated. This is set at the GPS receiver. If this
telegram is not transmitted, it is not indicated that a DGPS is connected to the AIS.
To check, that a DGPS is connected correctly, check the AIS State Menu of the connected RADAR-
PILOT/CHARTRADAR.
3.2.6 Emergency Power Source
It is recommended that an emergency power source such as an uninterruptible power supply is used. See
Section 7 for information about the power consumption of the Electronics Unit.
3.2.7 Pilot Port, Connector/Cable Kits
The regulations for AIS systems prescribe a connector for the Pilot Port. This connector is standardized.
The following kits are available:
Kit Consisting of Order No.
Panel mounting
Connector 9 pole (male), for panel mounting with 3 m cable
(NG3030G014)
300006056
Free hanging
Connector 9 pole "free hanging" (male) with 10 m cable
(NG3030G013)
300006049