User's Manual
Table Of Contents
- List of Contents
- List of Figures
- List of Abbreviations
- 1 General
- 2 Overview
- 2.1 Compatibility with Other Systems
- 2.2 AIS 3410 in RADARPILOT 1000/1100 Systems
- 2.3 AIS 3410 in 1000/1100 Series Systems (NACOS xx-4 and xx-5)
- 2.4 AIS 3410 in CHARTPILOT Stand-alone Systems
- 2.5 AIS 3410 in NACOS xx-3 Systems (Radar 9xxx and CHARTPILOT)
- 2.6 AIS 3410 in Radar 9xxx Systems with RADARPILOT 1000/1100
- 2.7 AIS 3410 in Radar 9xxx Systems
- 2.8 Housing of the 3410 Electronics Unit
- 2.9 Replacement of AIS Electronics Unit
- 2.10 Media Converter Installation (necessary for ships with BNC LAN networks)
- 3 Installation Recommendations
- 3.1 General Recommendations
- 3.2 Specific Recommendations
- 3.2.1 Recommendations Concerning AIS Systems
- 3.2.2 Recommendations Concerning the Installation of the Electronics Unit
- 3.2.3 Recommendations Concerning the Installation of the Antennas
- 3.2.4 Recommendations Concerning Redundancy
- 3.2.5 Recommendations Concerning the Connection of a (D)GPS to AIS 3410
- 3.2.6 Emergency Power Source
- 3.2.7 Pilot Port, Connector/Cable Kits
- 3.2.8 Recommendations Concerning AIS Stand-alone with Radar 9xxx / NACOS xx-2/-3
- 3.2.9 Recommendations Concerning the Connection to a Radar 1000/1100 Series System
- 3.2.10 Recommendations Concerning the Connection to a Radar 1100 Series System
- 4 Functional Description
- 4.1 Block Diagram
- 4.2 Termination
- 4.3 Description of the Components
- 4.3.1 AIS 3410 Electronics Unit
- 4.3.1.1 Interfaces
- 4.3.1.2 Internal Connectors
- 4.3.1.3 Supported Sensor Input Sentences
- 4.3.1.4 Supported Sentences for the AIS Primary Display Port and the Pilot Port
- 4.3.1.5 Supported Sentences for the Long Range Port
- 4.3.1.6 Supported Sentences for the Internal Position Sensor
- 4.3.1.7 IEC 61162 -1/-2 Interfaces, Electrical Characteristics
- 4.3.1.8 Example for the Interconnection
- 4.3.2 VHF Antenna
- 4.3.3 GPS Antenna
- 4.3.4 Pilot Port
- 4.3.1 AIS 3410 Electronics Unit
- 5 Setting-to-Work/Configuration
- 6 Repair/Maintenance
- 7 Technical Data
- 8 Fault Code List
- 9 Cabling Documents
- 10 Outline Drawings
- Notes
AIS 3410, Electronics Unit
ED3047G842 / 01 (2009-08)
Technical Manual
3 Installation Recommendations
3.1 General Recommendations
t_ue_e03.fm / 27.08.09
21
3 Installation Recommendations
3.1 General Recommendations
3.1.1 Cables
Cable types, cable data, maximum cable length, special instructions for cable laying and connection
details are defined in the Cabling Documents of the corresponding equipment (consisting of schematic
diagram, remarks, cable list and connection diagram).
Interface connections should be discussed and agreed with SAM Electronics
In order to ensure proper functioning of the equipment, the cable types should be selected according to
the cable lists.
In general, the following points must be taken into account:
-For the cables inside the units (cabinets), an extra length of 1 metre is necessary at each end. If
the height of the unit exceeds 0.5 metre, an extension by 1 m plus the height of the cabinet is neces
-
sary.
- All cables should be kept as short as possible, especially coaxial cables to minimize attenuation of
signal.
In order to fulfil all abovementioned requirements, install cables in two steps:
Install cables and leave extra length of 1 metre or more as described above
Cut cables to correct length in order to reach its terminal, but do not leave extra lengths furled
inside or outside the cabinet
-The cables must be marked by the electrician at both ends with the cable numbers corresponding
to the SAM Electronics cabling documents.
- Where necessary, particular cable glands - marked with letters and/or numbers - are assigned to
the cables.
The identification letters and numbers are stated in the connection diagrams; they are either fixed to
the unit or can be seen from the outline drawings (...BZ or ...MB).
- All connectors installed outdoors (e.g. on coaxial cables) should be waterproof by design to protect
against water penetration into the cable.
- Coaxial cables should be installed in separate signal cable channels/tubes and at least 10 cm away
from power supply cables. Crossing of cables should be done at right angles (90°). Coaxial cables
should not have any to sharp bends, which may lead to a change in the characteristic impedance of
the cable. The minimum bend radius should be 5 times the cable’s outside diameter.
- It must be ensured that all cables - including their screens - are passed into the units in contin-
uous lengths and are not terminated before reaching the destination equipment.
-With multicore cables, it is useful to strip down and lace the single wires according to the terminal
sequence.
- Existing cable grippers in the units must be used.
- All cable connections must be carefully checked after completion of the cable work and all cable
screens must be grounded via the shortest possible connections - if not stated otherwise in the
Cabling Documents/Connection Diagram.