3 Target Handling
3.3 Displaying Targets of Equipment Class B
b_ai_e03.fm / 19.12.02
18
To specify the source of the data that are to be displayed, there are two possible operating procedures:
Selection by means of the ENTER key:
By repeated pressing of ENTER, the displayed targets (and own ship) are marked one after another and
the corresponding data are displayed.
Selection by means of arrow keys:
Press one of the arrow keys. As a result, the cursor appears in the Situation Display. The point of inter-
section between both lines is cursor position. To select the target move the cursor to the target by means
of the arrow keys, and press ENTER.
☞ If the interval between the pressing of the keys is longer than 5 seconds, the cursor disappears.
3.3 Displaying Targets of Equipment Class B
The display of the Class A targets (ships to which the provisions of the SOLAS Convention apply) is
always switched on and cannot be deactivated.
Class B targets too (ships to which the provisions of the SOLAS Convention not apply and which are
equipped with an AIS system) can be displayed.
Switching the display of Class B targets on and off is done in the SETTINGS dialog, in the field DISPLAY
CLASS B TARGETS.
The restricted number of displayable targets includes also Class B targets i.e. thus, when the Class B
targets are switched on, this can make Class A targets disappear from the displays. Depending on the
nautical situation it may be recommendable to deselect the Class B targets.
1. Press MENU.
2. In the menu, mark SETTINGS by means of the ArrowUp/ArrowDown keys and press
ENTER.
3. In the SETTINGS dialog, mark the field DISPLAY CLASS B TARGETS by means of the
ArrowUp/ArrowDown keys and press ENTER.
4. Set the entry to On or Off by means of the ArrowUp/ArrowDown keys and press
ENTER.
Back: Press BACK twice.
Operating Sequence