User's Instructions

DCU DEBEG 3401
ED 3047 G 122 / – (2002-12)
Operating Instructions
3 Target Handling
3.3 Displaying Targets of Equipment Class B
b_ai_e03.fm / 19.12.02
18
To specify the source of the data that are to be displayed, there are two possible operating procedures:
Selection by means of the ENTER key:
By repeated pressing of ENTER, the displayed targets (and own ship) are marked one after another and
the corresponding data are displayed.
Selection by means of arrow keys:
Press one of the arrow keys. As a result, the cursor appears in the Situation Display. The point of inter-
section between both lines is cursor position. To select the target move the cursor to the target by means
of the arrow keys, and press ENTER.
If the interval between the pressing of the keys is longer than 5 seconds, the cursor disappears.
3.3 Displaying Targets of Equipment Class B
The display of the Class A targets (ships to which the provisions of the SOLAS Convention apply) is
always switched on and cannot be deactivated.
Class B targets too (ships to which the provisions of the SOLAS Convention not apply and which are
equipped with an AIS system) can be displayed.
Switching the display of Class B targets on and off is done in the SETTINGS dialog, in the field DISPLAY
CLASS B TARGETS.
The restricted number of displayable targets includes also Class B targets i.e. thus, when the Class B
targets are switched on, this can make Class A targets disappear from the displays. Depending on the
nautical situation it may be recommendable to deselect the Class B targets.
1. Press MENU.
2. In the menu, mark SETTINGS by means of the ArrowUp/ArrowDown keys and press
ENTER.
3. In the SETTINGS dialog, mark the field DISPLAY CLASS B TARGETS by means of the
ArrowUp/ArrowDown keys and press ENTER.
4. Set the entry to On or Off by means of the ArrowUp/ArrowDown keys and press
ENTER.
Back: Press BACK twice.
Operating Sequence