Install Manual

Compressor Controller Installation Guide & Information
Compresor Controller Model CCR100 and CCR200
Connections
Sensor Connections The compressor controller uses the digital pressure sensor, pump
temperature sensor and ambient temperature and humidity sensors, both are included with the
compressor controller and all need to be properly installed
Name / Function
Required / Location
Typical Installation
Pressure Sensor
Mesures real-time pressure
Yes,
Located typically where the
mechanical switch is installed
onto the tank
Installed on air tank with a tee
that connect to the manual
pressure release valve and
pressure gauge.
Pump Temperature Sensor
Is a ring cable shoe
thermocouple that Measures
the real-time temperature of
the air compressor pump
Yes.
Tightened down by a bolt on
the compressor pump(s)
connection of the piston
housing and pump base
Installed on to compressor
pump head
Ambient Temperature and
Humidity Sensor
Measures the real time
environmental temperature
and humidity
Yes,
Installed within an enclosure
that is near the air
compressor intake, protected
from direct sun and rain
Installed at the bottom of the
enclosure
Pressure settings The (low/on and high/off ) pressure cut on / off settings are digitally set by
user, on the back panel of the compressor controller and it can be set anywhere between the
range of minimum and maximum, the standard Compressor Controller ships with the following
pressure ranges:
Standard Pressure Range:
Minimum: 40PSI Maximum: 160psi
Other ranges are available (up to 5,000PSI) as custom order options, please contact SAM
Controllers for more information.
Page 6 Compressor Controller Model CCR100
and CCR200
, a product by SAM Controllers
This document can be downloaded at:
samcontrollers.com/download/compressor-install-guide/