Specifications
37
14. Communication ProConnect ↔ Combi steamer
14.1 Start up communication ProConnect ↔ Combi steamer
• Use the appropriate cable to establish a communicating connection between PC and combi
steamer, “Point-to-Point” connection RS 232.
• Plug the connecting cable to external SubD9 port in the hose shower tulip and connect
the other end to the PC.
• The combi steamer is in standby mode, it may be necessary to switch off the combi steamer.
• The PC is switched on and ProConnect is started
• Set the device address of the combi steamer in the PCPrg:
Menue/Options/device address.
• Set Com-Port in the PCPrg to the one used as interface for the connection
PCPrg ↔ Combi steamer.
• Provided the connection is established via USB-Port of the PC and USB/RS 232 adapter, this
interface is also indicated as Com-Port on the PC.
• It is possible to test the communication in the set-up dialog for device address and port,
“check communication”.
• Of course, there are further individual possibilities for connection and connectivity via RS 485
systems.
• Contact our Service Hotline or our sales department for further information.
14.2. Connection to Kitchen control systems (KCS)
• In case special hard/software is available, a connection to kitchen control systems is possible.
15. Accessories - Optional Extras
Lower rack/support 6x2/3 open, 10 levels
Wall brackets 1 pair
Fat/grease filter Recommendation: Additional filter for changing
Cleaning agent
Original MULTI CLEAN special
1 l spray-pistol bottle
10 l refill bin
Pressure pump sprayer Contents 1,5 l
Grids GN 2/3 chromium plated or stainless steel
Baking trays GN 2/3 20 mm stainless steel or enamelled
aluminium perforated and/or silicone coated
Pans GN 2/3 40, 65, 100 mm deep
stainless steel or enamelled, perforated or closed
or
RS 232
Connection