Specifications
27
7.7 Cleaning the cooking chamber
7.7.1 Automatic self cleaning Autoclean
• Prior to starting autoclean, make sure that enough cleaning products are available – visual control.
• Touch sensor key Special Program.
• Select autoclean with the sensor key.
• Use the arrows
or to select the desired autoclean cleaning step and start with .
• By pressing key Program Info a list appears, explaining details of the different cleaning steps.
• Start up can be reached via the directional arrow .
Autoclean programs:
According to the degree of dirt inside the cooking chamber, different programs can be chosen.
Display
Duration
Program steps
Step 1
45 minutes Soak - 1 x Clean - Rinse - Dry
Step 2
1 hour 15 min. Soak - 2 x Clean - Rinse - Dry
Step 3
1 hour 45 min. Soak - 3 x Clean - Rinse - Dry
Step 4
2 hours 15 min. Soak - 4 x Clean - Rinse - Dry
Flushing
approx. 2 min. Quick flushing with clear water
Start up
approx. 2 min. Filling of the tubes
Manual cleaning
• Whenever the cooking chamber temperature is too high, the cool-down function starts automatically
and cools the appliance down to 80° C. The display indicates “Unit cooling-down“.
• Once the temperature is reached, the appliance starts autoclean automatically.
• A manual cool down with open door is not necessary.
7.7.2 Delay start of autoclean
• It is possible to have the cleaning started automatically within a period of up to 24 hours.
Select autoclean on the screen “Special programs” and press sensor key Start Time!
Start Time can be pre-programmed. Press Start/Stop.
• The autoclean program is recorded.
• See Sec. 10.2.1 and make sure, the correct date and time is set.
7.7.3 Selection and printing of recorded autoclean protocols
• Go to the function HACCP Sec. 7.6 and proceed to 7.6.2
• Select the week day desired by scrolling and confirm with OK.
• Select the autoclean program to be printed and press sensor key Print.
• Press sensor key Print 7 to have all protocols of the last seven days printed, including the autoclean
programs.
Programm Info
Manual
Input
Autoclean
HACCP
Special
Menu
back
Menu
back
Start
Time
Program
Info
Help