Specifications
- 20 -
7. Valuable information
7.1 Error Message
Error Description Reaction, error remedy
Err001
Doors open Pause! Close doors or remedy defect on door switch.
Err113
Core temperature
sensor no signal.
Warning! (Delete by turning knob) Remedy sensor
interruption on 1.
Emergency operation with core temperature
measurement is possible!
Err114
Core temperature
sensor no signal.
Warning! (Delete by turning knob) Remedy sensor
interruption on 2.
Emergency operation with core temperature
measurement is possible!
Err115
Core temperature
sensor no signal.
Warning! (Delete by turning knob) Remedy sensor
interruption on 3.
Emergency operation with core temperature
measurement is possible!
Err116
Core temperature
sensor no signal.
Warning! (Delete by turning knob) Remedy sensor
interruption on 4.
Emergency operation with core temperature
measurement is possible!
Err117
Water vapour
elimination sensor, no
signal
Warning! Remedy sensor interruption on sensor.
Operation with a defective sensor is possible!
Err311
No water pressure. Cooking operation: Warning / autoclean: Pause Open
water valve. Remedy too low customer-side water
pressure. Check the pressure switch for proper
functioning.Attention!.
The appliance pauses in autoclean!.
The appliance can be used without water in cooking
operation!
Err313
Hand shower is
switched off.
The hand shower is switched off and appears as
acknowledgable message.