Specifications
- 19 -
6. Unit parameters
6.1 Adjustment of operational parameters
All operational parameters are correctly set when the Combi-Steamer is delivered.
However, if it is necessary to change time and date (summer/winter time, incorrect setting)
proceed as follows:
The unit must be switched on but with no program
Set the time to 1:23 and press the key “Manual humidification“ for about 2 seconds.
Adjust the different parameters at the panel in accordance with the table below.
Level Pos Description Min Max Standard
ServicePrg
Adjustment
1 101 Hours 0 23 00-23
1 102 Minutes 0 59 00-59
1 103 Day 1 31 1-31
1 104 Month 1 12 1-12
1 105 Year 0 99 0-99
1 106 Format Date 0 1 0 = DMY24; 1:DMY2
1 107 Summer/winter time switch 0 1 0: off; 1: Europe
1 108 Notation °C,°F 0 1 0: °C ; 1: °F
1 109 Language 0 1 0: German; 1: English
1 110 Beep duration Program end 0 999 sec 30 sec
1 111 Beep duration cooking step end 0 10 sec 0
1 112 Show Mode 0 1 0: off; 1: on
1 113 Internal light off – door open 0 1 0: off; 1: on
1 114 Address of appliance 0 99
1 115 Protocol core temperature 0 30 sec
Protokoll Typ 1
1 117 No Cool-Down 0 1 0: Cool-Down enabled
1: Cool-Down disabled
1 118 Disconnectible hand shower 0 1 1= Hand shower on
0= Hand shower off
After all parameters have been set, respectively changed, press START/STOP.
The unit is again ready for work, time display indicates 0:00 and temperature display 99°C.
Display
time
Knob
Display
temperature
Knob
Display
core temperature
Knob