Specifications

- 13 -
Start HACCP protocol printing:
Press touch key “manual humidification“ for about 3 sec
Printing protocols always for one production day.
Turn rotary knob “time“ and set the desired day.
Turn rotary knob “temperature“ and set the desired month.
Turn rotary knob “core temperature“ and set the year.
Start printing:
Press START/STOP and the protocol is printed
Terminate HACCP:
Press touch key “manual humidification“, the basic setting reappears
automatically.
4.1.3 Printed protocol in °C
-----------------------------------------------------------------
Serial No. :100100
Unit type : GXC
Print date : 15.09.07 16:00
Total operating hours : 1
CT every 3 minutes
-----------------------------------------------------------------
Date : 15.09.2007
Product: : 8 9
15:00 1 Nominal 99°C Humidity 100%
15:10 1 00:10 h Hold time 00:10 h
15:20 2 Nominal 130°C Humidity 15%
15:30 2 00:10 h Hold time 00:10 h
15:40 3 Nominal 150°C Humidity 0%
15:40 3 CT °C :67
15:45 3 CT °C 20 23 26 29 31 34 37 40
16:00 3 CT °C 43 46 49 51 54 57 60 63 66
16:30 3 00:00 h Hold time 00:45 h
Total energy consumption: 1,4 kWh
-----------------------------------------------------------------
-----------------------------------------------------------------
Serial No. 100100
Unit type GXB
Print date 15.07.07 16:00
Total operating hours 1
CT every 3 minutes
-----------------------------------------------------------------
Date : 15.09.2007
Product LT
15:00 1 Nominal 99°C Humidity 15%
15:10 1 00:10 h Hold time 00:10 h
Total energy consumption: 0,5 kWh
-----------------------------------------------------------------
Î Total operating hours of the appliance
Î Date of cooking program
ÎProgram number
Î Program start
Î Cooking mode Steaming = 100% Humidity
Î Cooking mode Combisteaming = 15% Humidity
Î Cooking mode Convection = 0% Humidity
Î Recording of core temperature every 3 minutes
Î Hold time - period the set temperature was hold.
Î Energy consumption of the program
Î Cooking mode LT cooking = 15% Humidity