User Manual

AUTO mode – NSB function Heating / Cooling mode Factory reset
Installer mode
Installer parameters
The
NSB (Night Setback) function enables automatic reduction of
the temperature setpoint on the HTRS230(30) SLAVE thermostat, via
the HTRP230(50) programmable MASTER thermostat connected to the
wiring centre (or other external clock). The temperature change takes
place between the comfort temperature mode and economic
temperature mode.
To activate AUTO mode, select the icon. Together with the icon,
the thermostat shows the active temperature mode on the display:
or .
If you made a mistake, want to change the thermostat parameters or
return to factory settings, follow the steps below.
Manual change:
Modes are indicated by symbols.
Press and hold button to enter the menu, then use button to select
the Heating / Cooling mode change setting. Conrm changes using
button. Now use or buttons to set the heating or cooling mode.
Conrm by button.
Automatic change (via CO terminal):
The heating/cooling mode can be changed automatically via the CO
terminal in the thermostat. If 230 V AC power supply is connected to the
CO terminal – then thermostat automatically switches to cooling mode.
If you want to use this function, then you have to change the value of the
d18 parameter to "1".
Cooling blocking:
When D19 thermostat parameter is set to "1", then cooling is blocked
for a single room. When the cooling function is blocked, no message is
displayed.
Press any button to highlight the screen, then follow the steps
below:
Press any button to highlight the screen, then follow the steps
below:
Press any button to highlight the screen, then follow the steps
below:
Select AUTO mode using
or buttons.
1 2
Note:For the proper NSB function work, an appropriate cable
connection is required.The connection description is on the
previous page.
Note:This action will permanently delete all current settings.
Note:Calibration of the temperature can also be set in the
installer parameters (parameter d02).
The thermostat allows to correct the displayed temperature by ±3.0°C.
Follow the steps below:
Calibration of displayed temperature – "oset"
function
Press any button to highlight the screen, then follow the steps
below:
1
3
2
4
Press and hold button to
enter the menu.
Press and hold
and
buttons simultaneously for
3 seconds.
Press and hold
and
buttons simultaneously for
3 seconds.
Conrm by
button.
Select the 49 code using or
buttons.
Press button to reset the
thermostat.
Conrm by button.
You are now in the installer
menu.
Select the parameter you wish
to change by
or buttons
and enter using button.
Use and to set the value
of the parameter, and then
conrm it with .
Select the 47 code using
or buttons.
Conrm "oset" setting by
button.
Set the temperature
calibration value using
or buttons.
Temperature calibration can be
made in the range from -3.0°C
to +3.0°C. Conrm the selected
value by button.
1
3
2
4
5
1
3
2
4
Function
Param-
eter
Values
Description
Default
Values
d01 Heating Control
0
According
to the PWM
algorithm
01
Hysteresis:
0.5 °C
(± 0.25 °C)
2
Hysteresis:
1.0 °C
(± 0.5 °C)
d02
Displayed
temperature
correction
from
-3.0°C
to +3.0°C
If the thermo-
stat indicates
an incorrect
temperature,
then it can
be corrected
±3.0°C
0.0°C
d05 Cooling Control
1
Hysteresis:
0.5 °C
(± 0.25 °C)
2
2
Hysteresis:
1.0 °C
(± 0.5 °C)
d07 Valve Protection
0 Disabled
1
1 Enabled
d08
Frost protection
setpoint
5.0 –
17.0°C
The frost
protection
temperature is
maintained for
example during
active holiday
mode.
5.0°C
d12
Heating setpoint
limits
5.0 –
35.0°C
Maximum
temperature
which can be
set for heating
35.0°C
d13 Cooling setpoint limits
5.0 –
40.0°C
Minimum
temperature
which can be
set for cooling
5.0°C
d18
Heat/Cool Mode
Selection
0
Manual by
buttons use
0
1
Automatic by
the CO terminal
d19
Cooling Blocking
function
0
Cooling
allowed
0
1
Cooling
disabled
d20
Actuators loading
selection for dierent
temperature
compensation
0 – 5
Numbers 1
to 5 are the
numbers of
actuators con-
nected to the
thermostat.
0
3 sec.
3 sec.
3 sec.
3 sec.