Tus neeg siv phau ntawv
Table Of Contents
- 1Brief Introduction
- 2Product features
- 3Functions
- 4Typical application
- 1Model confirmation
- 2Appearance inspection
- 1Environmental requirements
- 2Selection of power line
- 3Power supply requirements
- 4Electrostatic protection (ESD)
- 5Input/output port protection
- 6Cleaning of display of front panel
- 1Battery description
- 2Battery installation and replacement
- 3Battery status check
- 4 Battery charging
- 1Start-up of spectrum analyzer
- 2Shutdown of spectrum analyzer
- 1Display zone
- 2Number input zone
- 3Function key zone
- 4Reset button
- 5Power switch
- 1Channel power measurement
- 2Occupied bandwidth measurement
- 3Adjacent channel power ratio measurement
- 4Third-order IM distortion measurement
- 5Drift signal measurement
- 6Noise signal measurement
- 7Distortion measurement
- 8Pulse RF signal measurement
- 9Signal source measurement (option)
- 10Coverage map (option)
- 1. Frequency menu
- 2. Span menu
- 3. IF output menu
- 4. Amplitude menu
- 5. Bandwidth menu
- 6. Detector menu
- 7. Marker menu
- 8. Peak menu
- 9 Mode menu
- 10 Sweep menu
- 11Triggering menu
- 12Trace menu
- 13Limit menu
- 14Measurement menu
- 15Signal source menu (option)
- 16Coverage map menu (option)
- 17File menu
- 18System menu
- 1Spectrogram measurement
- 2RSSI measurement
- 1Frequency menu
- 2Span menu
- 3Amplitude menu
- 4Bandwidth menu
- 5Marker menu
- 6Peak menu
- 7Sweep menu
- 8Auto Save menu
- 9Measurement menu
- 10File menu
- 1Frequency menu
- 2Amplitude menu
- 3Bandwidth menu
- 4Calibrate menu
- 5Limit menu
- 6File menu
- 1Frequency menu
- 2Span menu
- 3Amplitude menu
- 4Bandwidth menu
- 5Marker menu
- 6Peak menu
- 7RF spectrum menu
- 8Audio spectrum menu
- 9Audio waveform menu
- 10Measurement menu
- 11File menu
- 1Channel Scanner
- 2Frequency Scanner
- 3List scanner
- 1Sweep menu
- 2Channel Scanner menu
- 3Frequency Scanner menu
- 4List Scanner menu
- 5Measurement menu
- 6File menu
- 1[PScan]
- 2FScan
- 3MScan
- 1Frequency menu ([PScan] mode)
- 2Frequency menu ([FScan] mode)
- 3Amplitude menu
- 4Bandwidth menu
- 5Marker menu
- 6Peak menu
- 7Sweep/Antenna menu
- 8Demodulation menu
- 9Edit List menu
- 10Measurement menu
- 11File menu
- 1 Frequency menu
- 2 Span menu
- 3 Amplitude menu
- 4 Bandwidth menu
- 5 Marker menu
- 6 Peak menu
- 7 Sweep menu
- 8 Record menu
- 9 Configuration menu
- 10 Tune listen menu
- 11 IQ capture menu
- 12 ShortCut menu
- 13 File menu
- Please refer to the file menu description under sp
- 1Point Scan
- 2Horizon Scan
- 3Map Location
- 1 Frequency menu
- 2 Amplitude menu
- 3 Bandwidth menu
- 4 Sweep/Antenna menu
- 5Demodulation menu
- 6Measurement menu
- 7Map menu
- 8File menu
Tel: 886.909 602 109 Email: sales@salukitec.com
www.salukitec.com
99
15 Signal source menu (option)
·[Signal Source Off On]: press [Measure] → [More 1 of 2]→[Generator]
→[Generator Off On], to activate or deactivate the signal source.
·[Tracking Mode Off On]: press[Measure]→[More 1 of 2] →[Signal
Source] →[Mode CW Track], to activate or deactivate the signal source
tracking mode.
·[Special Notice]: the tracking mode switch is effective when the signal
source switch is started. In case of Off, the independent source mode and
the point frequency source output will be activated independent of spectral
analysis. At this time, the set point frequency and output power menus will
be effective but the transmission measurement, power offset and
frequency offset menus are ineffective; in case of Track, the tracking mode
will be activated, the synchronous scanning will be done at signal source
frequency and spectral analysis mode frequency, the set point frequency
menu will be infective, and the output power, power offset, frequency offset
and transmission measurement will be effective.
·[power 0.0 dBm]: press [Measure]→[More 1 of 2] →[Generator] →
[Power 0.0dBm], to change the output power by using number key or key
[↑] or[↓].
·[Special Notice]: the output power range is -40dBm~0dBm with step size
of 1dB.
·[CW Freq 1.000GHz]: press [Measure] →[More 1 of 2] →[Generator]
→[CW Freq 1.000GHz], to change the CW frequency by using number
key or key [↑] or [↓].
·[Power Offset 0.0dB]: press [Measure]→[More 1 of 2]→[Generator] →
[Power Offset 0.0dB]. When there is gain or loss between generator output
and peripheral equipment, it is allowed to use this parameter to set the
signal source power offset so as to indicate the actual power of system.
This parameter cannot change the actual output power of generator but its
power reading.
·[Special Notice]: The parameter range is -200dB~200dB with default
value of 0dB and step size of 1dB, which is effective when the
tracking mode is activated.
·[Freq Offset 0.000Hz]: press [Measure] →[More 1 of 2] →[Generator]
→[Freq Offset 0.000Hz], to set the offset value of generator output signal