Tus neeg siv phau ntawv
Table Of Contents
- 1Brief Introduction
- 2Product features
- 3Functions
- 4Typical application
- 1Model confirmation
- 2Appearance inspection
- 1Environmental requirements
- 2Selection of power line
- 3Power supply requirements
- 4Electrostatic protection (ESD)
- 5Input/output port protection
- 6Cleaning of display of front panel
- 1Battery description
- 2Battery installation and replacement
- 3Battery status check
- 4 Battery charging
- 1Start-up of spectrum analyzer
- 2Shutdown of spectrum analyzer
- 1Display zone
- 2Number input zone
- 3Function key zone
- 4Reset button
- 5Power switch
- 1Channel power measurement
- 2Occupied bandwidth measurement
- 3Adjacent channel power ratio measurement
- 4Third-order IM distortion measurement
- 5Drift signal measurement
- 6Noise signal measurement
- 7Distortion measurement
- 8Pulse RF signal measurement
- 9Signal source measurement (option)
- 10Coverage map (option)
- 1. Frequency menu
- 2. Span menu
- 3. IF output menu
- 4. Amplitude menu
- 5. Bandwidth menu
- 6. Detector menu
- 7. Marker menu
- 8. Peak menu
- 9 Mode menu
- 10 Sweep menu
- 11Triggering menu
- 12Trace menu
- 13Limit menu
- 14Measurement menu
- 15Signal source menu (option)
- 16Coverage map menu (option)
- 17File menu
- 18System menu
- 1Spectrogram measurement
- 2RSSI measurement
- 1Frequency menu
- 2Span menu
- 3Amplitude menu
- 4Bandwidth menu
- 5Marker menu
- 6Peak menu
- 7Sweep menu
- 8Auto Save menu
- 9Measurement menu
- 10File menu
- 1Frequency menu
- 2Amplitude menu
- 3Bandwidth menu
- 4Calibrate menu
- 5Limit menu
- 6File menu
- 1Frequency menu
- 2Span menu
- 3Amplitude menu
- 4Bandwidth menu
- 5Marker menu
- 6Peak menu
- 7RF spectrum menu
- 8Audio spectrum menu
- 9Audio waveform menu
- 10Measurement menu
- 11File menu
- 1Channel Scanner
- 2Frequency Scanner
- 3List scanner
- 1Sweep menu
- 2Channel Scanner menu
- 3Frequency Scanner menu
- 4List Scanner menu
- 5Measurement menu
- 6File menu
- 1[PScan]
- 2FScan
- 3MScan
- 1Frequency menu ([PScan] mode)
- 2Frequency menu ([FScan] mode)
- 3Amplitude menu
- 4Bandwidth menu
- 5Marker menu
- 6Peak menu
- 7Sweep/Antenna menu
- 8Demodulation menu
- 9Edit List menu
- 10Measurement menu
- 11File menu
- 1 Frequency menu
- 2 Span menu
- 3 Amplitude menu
- 4 Bandwidth menu
- 5 Marker menu
- 6 Peak menu
- 7 Sweep menu
- 8 Record menu
- 9 Configuration menu
- 10 Tune listen menu
- 11 IQ capture menu
- 12 ShortCut menu
- 13 File menu
- Please refer to the file menu description under sp
- 1Point Scan
- 2Horizon Scan
- 3Map Location
- 1 Frequency menu
- 2 Amplitude menu
- 3 Bandwidth menu
- 4 Sweep/Antenna menu
- 5Demodulation menu
- 6Measurement menu
- 7Map menu
- 8File menu
Tel: 886.909 602 109 Email: sales@salukitec.com
www.salukitec.com
198
Chapter XIII Troubleshooting and Repair
This chapter will introduce how to find out problems and receive the after-sales service. Interpretation of internal
errors of the spectrum analyzer is also included.
If you have any problem in operation of S3302 series spectrum analyzer or want to purchase related components,
options or accessories, we will provide complete after-sales services.
In general, the trouble is caused by failure of hardware/software or users' misuse. Please contact us immediately in
case of any trouble. If the warranty is valid, we will provide maintenance services free of charge according to the
commitment in the warranty; otherwise, we will charge costs.
Section 1 Fault Information Description
This section will help you to simply judge and deal with faults of S3302 series spectrum analyzer. If necessary, report the problems to us as accurately as
possible so that we can solve the problems as soon as possible.
You can check S3302 series instrument according to the following prompts in the case of any fault: Please contact
us if the failure cannot be removed.
If S3302 series cannot be started when the Power key is pressed, check whether the power supply is normal,
whether the adapter indicator is ON and whether the power supply battery is normal. If the above items are
normal, the instrument failure may occur. In this case, contact us for repair.
If the system or applicable program fails after start-up of S3302 series instrument, press [Reset] to recover the
known state. If S3302 still cannot work properly, an instrument failure may occur. In this case, contact us for
repair.
If the performance indicators of S3302 series are abnormal, check whether the test tools and test environment
conform to the requirements, whether the connector of the test port is damaged and whether the performance
indicators of the calibration kit are normal. If the above items are normal, instrument failure may occur. In this
case, contact us for repair.
If LAN communication of S3302 series fails. First check the IP address and the yellow indicator beside the LAN
interface on the top panel. If the indicator does not flicker, check the LAN cable and connections. If all the
above items are in good conditions, it indicates that the instrument may be faulty. Contact us for repair.