Tus neeg siv phau ntawv
Table Of Contents
- 1Brief Introduction
- 2Product features
- 3Functions
- 4Typical application
- 1Model confirmation
- 2Appearance inspection
- 1Environmental requirements
- 2Selection of power line
- 3Power supply requirements
- 4Electrostatic protection (ESD)
- 5Input/output port protection
- 6Cleaning of display of front panel
- 1Battery description
- 2Battery installation and replacement
- 3Battery status check
- 4 Battery charging
- 1Start-up of spectrum analyzer
- 2Shutdown of spectrum analyzer
- 1Display zone
- 2Number input zone
- 3Function key zone
- 4Reset button
- 5Power switch
- 1Channel power measurement
- 2Occupied bandwidth measurement
- 3Adjacent channel power ratio measurement
- 4Third-order IM distortion measurement
- 5Drift signal measurement
- 6Noise signal measurement
- 7Distortion measurement
- 8Pulse RF signal measurement
- 9Signal source measurement (option)
- 10Coverage map (option)
- 1. Frequency menu
- 2. Span menu
- 3. IF output menu
- 4. Amplitude menu
- 5. Bandwidth menu
- 6. Detector menu
- 7. Marker menu
- 8. Peak menu
- 9 Mode menu
- 10 Sweep menu
- 11Triggering menu
- 12Trace menu
- 13Limit menu
- 14Measurement menu
- 15Signal source menu (option)
- 16Coverage map menu (option)
- 17File menu
- 18System menu
- 1Spectrogram measurement
- 2RSSI measurement
- 1Frequency menu
- 2Span menu
- 3Amplitude menu
- 4Bandwidth menu
- 5Marker menu
- 6Peak menu
- 7Sweep menu
- 8Auto Save menu
- 9Measurement menu
- 10File menu
- 1Frequency menu
- 2Amplitude menu
- 3Bandwidth menu
- 4Calibrate menu
- 5Limit menu
- 6File menu
- 1Frequency menu
- 2Span menu
- 3Amplitude menu
- 4Bandwidth menu
- 5Marker menu
- 6Peak menu
- 7RF spectrum menu
- 8Audio spectrum menu
- 9Audio waveform menu
- 10Measurement menu
- 11File menu
- 1Channel Scanner
- 2Frequency Scanner
- 3List scanner
- 1Sweep menu
- 2Channel Scanner menu
- 3Frequency Scanner menu
- 4List Scanner menu
- 5Measurement menu
- 6File menu
- 1[PScan]
- 2FScan
- 3MScan
- 1Frequency menu ([PScan] mode)
- 2Frequency menu ([FScan] mode)
- 3Amplitude menu
- 4Bandwidth menu
- 5Marker menu
- 6Peak menu
- 7Sweep/Antenna menu
- 8Demodulation menu
- 9Edit List menu
- 10Measurement menu
- 11File menu
- 1 Frequency menu
- 2 Span menu
- 3 Amplitude menu
- 4 Bandwidth menu
- 5 Marker menu
- 6 Peak menu
- 7 Sweep menu
- 8 Record menu
- 9 Configuration menu
- 10 Tune listen menu
- 11 IQ capture menu
- 12 ShortCut menu
- 13 File menu
- Please refer to the file menu description under sp
- 1Point Scan
- 2Horizon Scan
- 3Map Location
- 1 Frequency menu
- 2 Amplitude menu
- 3 Bandwidth menu
- 4 Sweep/Antenna menu
- 5Demodulation menu
- 6Measurement menu
- 7Map menu
- 8File menu
Tel: 886.909 602 109 Email: sales@salukitec.com
www.salukitec.com
147
Chapter VIII Channel Scanner Mode (optional)
Section 1 Introduction to Typical Measurements
The channel scanner mode can be applied to measure the signal power of multiple channels. The signal power is
displayed in the bar graph or list form. At most, the signal power of 20 channels can be displayed. This can be
divided into three modes according to the channel setting: channel scanner, frequency scanner and list scanner.
Channel scanner: Set the measured channel by setting the signal standard, starting channel and channel step.
Frequency scanner: Set the measured channel by setting the starting frequency and frequency step.
List Scanner: Set the measured channel by setting the list.
The bandwidth and number of measured channels can be set in the above three modes.
All operations in this chapter are based on the channel scanner mode, which will not be separately described below.
1 Channel Scanner
Below is an example of the Channel Scanner mode, mainly involving the following procedures.
1) Press [Sweep]→ [Channel Scanner] → [Signal Std], and set the signal standard of measurement.
2) Press [Sweep]→[Channel Scanner]→[Start Channel] and set the starting channel of measurement. In this case,
the starting channel should meet the requirements of the selected signal standard.
3) Press [Sweep]→[Channel Scanner] →[Number of Channels], and set the number of measured channels. At
most 20 channels can be measured at the same time.
4) Press [Sweep]→[Channel Scanner] →[Channel Step] and set the channel step of measurement. A certain
number of channels will be measured with the starting channel as the initial channel, based on the set channel step.
5) Press [Sweep]→ [Display Graph Table] and enable the graph display mode.
6) Press [Sweep]→[Power Display Curr Max] and enable the maximum option. Set the maximum power of each
displayed channel.