Product Brochure

Sakrete.com • 866-725-7383
The Pro’s Choice Since 1936
Non-Shrink Grout
Technical Data cont.:
NOTE: Test results obtained under controlled laboratory conditions at 73
0
F (23
0
C) and 50% humidity.
More or less water may be required to achieve the desired mixing consistency depending on the atmo-
spheric conditions and job site conditions. Do not exceed 4.75 qts (4.5 L) water per 50 lb (22.7 kg) bag.
Preparation/Application:
Refer to:
- ACI 302.1 Guide for Concrete Flooring and Slab Construction
- ACI 304.1 Guide for Measuring, Mixing, Transportation and Placing Concrete.
NOTE: it is the responsibility of the installer/applicator to ensure the suitability of the product for its
intended use.
1. Use only when the product, air, and surface temperature are above 40
0
F
(4
0
C) for a minimum of 24 hours.
2. Clean area and remove all unsound concrete, grease, oil, paint, and any
other foreign material that will inhibit performance.
3. Prior to grout placement, all surfaces must be clean and saturated with
water for 24 hours. Remove excess water bringing it to a surface saturated
dry condition (SSD).
4. Provide air relief holes where necessary if grouting is beneath large plates.
5. Wood form work or other absorbent forms should be coated with a form
release oil to prevent grout adherence and water absorption.
6. Design form work to facilitate rapid, continuous and complete filling of the
space to be grouted. Rodding the grout lightly will help move material.
7. Use methods that will enable the grout to flow by gravity between the
surfaces and keep the grout in full contact with these surfaces until it has
hardened.
Sakrete
®
Non-Shrink Construction
Grout is non-shrink and non-metal-
lic. When properly mixed to a fluid
consistency allows for pumping
grout to areas where it is difficult to
access using conventional grouting
methods.
Features:
Meets or exceeds ASTM C1107 (Plastic and Flowable)
Non-corrosive, will not attack reinforcement
Non-shrink
Non-metallic, Non-staining
High strength
Pumpable for easy placement
Meets Corps of Engineers Specification CRD-C 621
Use For:
Structural grouting and general purpose structural grouting:
For use above, at or below grade
Column bases
Anchor bolts
Machinery bases
Sole plates
Tilt-up panels
Steel bearing plates
Reinforcing steel in block cells
Dowel rods
Transfer lines
Concrete - poured in place, precast, tilt-up and prestressed
Yield/Water/Coverage:
NOTE: Yield and water are approximate. The yield above does not allow for waste and spillage.
Color:
Gray
Technical Data:
DIVISION 9
Non-shrink Grouting
03 62 00
Bag Size Coverage Water
50 lb (22.7 kg) 0.45 ft
3
(12.7 L) Flowable: 1 gal (3.8 L)
Plastic: 3 qts + 1 pt (3.3 L)
Precision
Non-Shrink Grout
Flowable Plastic
Bag size 50 lb (22.7 kg) 50 lb (22.7 kg)
Approx. water
content per bag
1 gal (3.8 L) 3 qts + 1 pt (3.3 L)
Flow, ASTM C939
Flow, at 5 drops,
ASTM C1437
125-145 100-125
Compressive strength, ASTM C109
24 hours 2,000 psi
(14 MPa)
3,000 psi
(21 MPa)
7 days 6,000 psi
(43 MPa)
6,500 psi
(45 MPa)
28 days 8,000 psi
(55 MPa)
9,000 psi
(62 MPa)
C-827 expansion 0 - 0.4 0 - 0.4
Height change, ASTM C1090
1, 3, 7 and 28 days 0 - 0.2 0 - 0.2

Summary of content (2 pages)