In v e r t er Type
Sun u n o - TL1.5K
Sun u n o - TL2K
Sun u n o - TL3KB
Sun u n o - TL4KB
Su nuno- TL3K A ,
SU 3KMTL I
Su nuno- TL4K A ,
SU 4KMTL I
Su nuno- TL5K ,
SU 5KMTL I
MPP Tracker
1
Max.DC Voltage
550V
·
connected at input zone 1 and the negative pole at input
zone 2, this is called a mixed connection.
·Only connect strings at one input zone and never mix
the input zones 1 and 2!
For instance, if the positive pole of a string is
NOTICE
The DC connectors come pre-assembled and the caps are loose. The whole
connector will include the male side and female side as showed below:
Figure 6.8
·
make sure the inverter is isolated and disconnected from
the PV source and AC grid.
·
Before electrical connection setup, installer shall
The inverter may only be operated with PV generators
(Class A PV modules according to IEC 61730 and
cabling) of protection class II. Do not connect any
sources of energy other than PV modules to the inverter.
NOTICE
·
please use the sealing plug to seal the left DC input set to
ensure the inverter IP 65 protection.
If only one string input is used for DC connection,
NOTICE
·
·
DANGER to life due to potential fire or electricity shock.
Never connect or disconnect the connectors under load.
DANGER
Max. DC
Power (W)
Max.DC
Current/per string(A)
2
18 0 0
23 0 0
34 0 0
45 0 0
42 0 0
52 0 0
480V
11
12
17
20
21 A / 1 5 A
26 A / 1 6 A
Female side connector (F)
Male side connector (M)
No mixed connections between input zones(for Sununo-
T L 3 K B / 4 K B a n d S u n u n o - T L 3 K A / 4 K A / 5 K ,
S U 3 K M T L I / S U 4 K M T L I / S U 5 K M T L I ) .
For Sununo – TL 1.5K/2K/3KB/4KB, there is just one MPP Tracker. These
single MPPT inverters require same type module same quantity, identical
alignment and tilt.
For SununoTL3KA/4KA/5K,SU3KMTLI/SU4KMTLI/SU5KMTLI, there are
two MPP Trackers for the two string inputs. Unlike the traditional single MPPT
inverters which require same type module, same quantity, identical alignment
and tilt, the multi-MPPT SAJ grid-tie inverters can deal with different solar
modules, different quantity, different alignment and tilt, thus can withstand
harshest environmental conditions.
with
16A/15A
3200