Specifications

Electrical Precautions
The ground fault circuit interruptor (ground leakage circuit
breaker), fuses, gauges, wiring, power points, ground con-
nection, and cut-off devices for the various power supplies,
must be in good condition and comply with the connecting
power of this machine as indicated on manufacturers
name plate.
Personnel Precautions.
1. Operators must wear face shield, gloves and non-flam-
mable clothing for protection against sparks.
2. Electrode force may exceed 400 pounds. Keep body
clear of welding guns moving parts.
3. DO NOT wear rings, watches or any objects that may
conduct electricity as they can overheat and cause
severe burns.
4. Persons with medical implants should not come within
10 feet (3 meters) of the welder or the vehicle being
repaired when welder is in use.
5. All of the machines protective panels must remain in
place and be in good condition.
6. Warning labels must remain in place and be in good
condition. On request Chief supplies replacement
labels.
7. Operators must be knowledgeable of the operation of
the welder before beginning work.
8. Work area should be well-lit and free of obstacles with
access to emergency stop switch.
IMPORTANT: In case of non-satisfactory welder opera-
tion, read this users manual for proper operating or
maintenance information. DO NOT remove panels to
look inside of machine. Place main switch to offposi-
tion, disconnect machine from electrical and air power
sources and call a Chief authorized representative.
!
R
CHIEF 2000 HERTZ DC INVERTER WELDER
USERS MANUAL
!
Rear Panel - Chief 2000 Hertz
DC InverterWelder
Unit Components (See Illustration Below)
1. Slide hammer.
2. Panel straighten-
ing accessory.
3. End piece for
dent pulling wedge
plates.
4. Electrode for seam
welds (series spots)
5. Electrode for stud welds,
2, 5 and 3mm.
6. Electrode for stud welds,
4 and 5mm.
7. Electrode for moulding rivet
welds.
8. Electrode for copper
shrinking.
9. Electrode for washer
welds.
10. Electrode for spot welds
and welding of nuts.
11. Carbon electrode for heat
shrinking.
2
1
11
2
3
4
5
678
9
10