Specifications

R
CHIEF 2000 HERTZ DC INVERTER WELDER
USERS MANUAL
Welding control indicators do not
light.
Machines circuit breaker trips.
Installation circuit breaker trips.
Self test message.
Test OK message.
Init Para message.
Tool err. message.
Curr. Peak message.
Stop ° F message
Gun Sens. message
Pist. Sens. message
Keyboard Err. message
Gun Trig. message.
Pist. Trig. message
Power supply fault.
Weak power supply.
Too low breaker or weak power sup-
ply
Normal when machine starts.
Normal when machine starts.
Appears after resetting timer.
Wrong tool selected on keyboard.
Inadequate electrical supply.
Overheating.
Faulty gun cable temp. sensor.
Faulty pistol cable temp. sensor.
Faulty keyboard (one key stuck).
Faulty gun switch.
Faulty pistol switch.
Check condition of main power line (unit connection,
fuses, main circuit-breaker, etc.). If no power supply prob-
lems, call an authorized Chief representative.
Inadequate electrical supply, too low initial voltage or
important drop of voltage during weld results in high sup-
ply amperage. Have installation checked (initial voltage,
length, size of wire, tightening of connections , etc.).
Check condition of main power line (unit connection,
fuses, main circuit-breaker, etc.).
Same as above. Change breaker to higher amperage type
if necessary. (60 amps - slow action type.)
Wait until machine finishes auto test.
Machine is OK ready to work in few seconds.
Procedure has been successful.
Select tool being used (gun/pistol) on keyboard.
Inadequate electrical supply, too low initial voltage or
important drop of voltage during weld results in high sup-
ply amperage. Have installation checked (initial voltage,
length, size of wire, tightening of connections, etc.).
Overheated cables, rectifier or transformer. Stop using
machine for approximately 30 minutes but let machine run
to allow fan to cool. If air does not flow in the cables, select
automatic cooling on keyboard.
Automatic cooling of gun cables may be erratic. Use man-
ual cooling control and call an authorized Chief represen-
tative.
Automatic cooling of pistol cables may be erratic. Use
manual cooling control and call an authorized Chief rep-
resentative.
Call an authorized Chief representative.
Gun switch stuck. Operate trigger to try to release the
switch. If no improvement, replace switch.
Pistol switch stuck. Operate trigger to try to release switch.
If no improvement, replace switch.
Diagnosis And Remedies
Fault Possible Cause Remedies