Specifications
R
CHIEF 2000 HERTZ DC INVERTER WELDER
USERS MANUAL
Dent Pulling
1. Fit slide hammer in pistol and fit wedge plate in slide
hammer. (See unit components - page 2.)
2. Clamp ground shoe to steel sheet (panel, etc.) prior to
welding wedge plate to dented portion of steel sheet.
NOTE: When welding wedge plate to steel sheet and
when pulling the dent, the ground shoe must be
clamped to the steel sheet to allow a flow of current
through the wedge plate and the steel sheet.
3. Select program and thickness of steel sheet.
NOTE: The power and time are preset and parameters
will automatically appear on the display. If the preset
parameters have been changed set power and time
according to the chart at right or reset the timer
as indicated on page 4 to recover the original facto-
ry settings.
4. Position the wedge plate in middle of dent and apply
very light pressure. Then pull the trigger.
IMPORTANT: Too much pressure may result in burning
through the panel.
5. Slowly straighten the dent by repeatedly tapping the slide
hammer. Then release the trigger and remove the
wedge plate by twisting the slide hammer.
IMPORTANT: Pressure must be constant during the
dent removal procedure. Remember, the lighter the
force, the greater the adhesion. Too much pres-
sure may result in burning through the panel.
Thickness Tim. - Pow.
0.8mm 2 - 22
1.0mm 2 - 24
1.2mm 2 - 28
1.5mm 2 - 30
Basic Settings
All Steels
9