User Manual

19
To connect the transmitter to a DMX console use a cable conforming to specifications EIA RS-
485: pole twisted, shielded, 120Ohm characteristic impedance and low capacity (SAGITTER SG
DMX3 – SG DMX5).
Do not use microphone cable or other cable with different characteristics than those specified.
Terminations must be made with male / female XLR 3-pin connectors. You must enter on the
last device a terminal plug with a 120Ohm resistance (min1 / 4 W) between terminals 2 and 3.
IMPORTANT: The cables must not come into contact with each other or with the metal housing
of the connectors. The housing itself must be connected to the shield braid and to pin 1 of the
connectors.
CABLE CONNECTION
Use a cable conforming to specifications EIA RS-485: pole twisted, shielded, 120Ohm
characteristic impedance and low capacity (SAGITTER SG DMX3 – SG DMX5).
Do not use microphone cable or other cable with different characteristics than those specified.
Terminations must be made with male / female XLR 3-pin connectors. You must enter on the
last device a terminal plug with a 120Ohm resistance (min1 / 4 W) between terminals 2 and 3.
IMPORTANT: The cables must not come into contact with each other or with the metal housing
of the connectors. The housing itself must be connected to the shield braid and to pin 1 of the
connectors.