User Manual

21
5.2 - CONNECTION TO THE MAINS
The device must be connected to a power supply system with a proper earth system.
Moreover, it is recommended to protect power supply lines of the products from indirect
contact and / or shorting to earth by using appropriately sized anti electrical shock switch.
The electrical connection must be carried out by a qualified electrician. Ensure that the mains
frequency and voltage correspond to those for which the device is designed, as shown in the
electrical data label.
5.3 - CONNECTION TO THE DMX CHAIN
Use a cable conforming to specifications EIA RS-485: pole twisted, shielded, 120Ohm
characteristic impedance and low capacity (SAGITTER SG DMX3 – SG DMX5).
Do not use microphone cable or other cable with different characteristics than those specified.
Terminations must be made with male / female XLR 3-pin connectors.
In case of chains with more than 10 pcs, it is suggested to use a DMX splitter (SG FASTERSP4
sold separately).
8
5. - INSTALLAZIONE ED ACCENSIONE
5.1 - INSTALLAZIONE PRODOTTO
- Non scuotere l'apparecchio. Evitare l'utilizzo di forza eccessiva durante le operazioni di
installazione o fissaggio dell'unità.
- L'unità può essere installata a pavimento in appoggio sugli appositi piedini, a parete, a soffitto
su truss o sull’apposito stativo.
ATTENZIONE! E'OBBLIGATORIO
il montaggio della fune di sicurezza (PLH232 –
PLH248 venduta separatamente) nel caso in cui il
prodotto sia appeso a parete, a soffitto o su truss.