5.3 - CONTROL MODES
AC 230V - Max. 30 bars in chain
AC 110V - Max. 15 bars in chain
IR remote controller
Connect Max. 30pcs (AC 230V) or 15pcs (AC 110V) lights in chain, set the first light on STAT
COLO or AUTO, other 29 or 14pcs lights set it SLAVE-RUN.
1. The light can be controlled by IR remote controller directly
2. Choose the static color. Press button "R","G" or "B" first, then the button "UP" and
"DOWN", you can adjust the static color of the light.
3. Choose the AUTO modes: It has twelve Auto modes for selecting. Press "AUTO 1" or
"AUTO 2", then press "UP" or "DOWN" to select the AUTO mode. Press "SPEED“, then
press “UP“ or "DOWN“ to select the AUTO speed.
4. Press "SLAVE" or "DMX" to select the SLAVE mode or DMX mode.
5. Connect 2 pieces or more lights, and set the first light in STAT COLO or AUTO mode,
while other lights in SLAVE mode by IR remote controller. Then other lights will run
following the first one in AUTO mode.
To ensure optimal performance, the unit must be frequently cleaned. Unplug the device
from the mains and let it cool for at least 35 minutes to avoid the risk of burns. Use a vacuum
cleaner or an air compressor and a soft brush or a lens cloth to remove the dust deposited.