4.2 - CONNECTION IN A CHAIN
AC 230V: connect maximum 30 bars in a chain
AC 110V: connect maximum 15 bars in a chain
The device must be connected to a power supply system with a proper earth system.
Moreover, it is recommended to protect power supply lines of the products from indirect
contact and / or shorting to earth by using appropriately sized anti electrical shock switch.
The electrical connection must be carried out by a qualified electrician. Ensure that the
mains frequency and voltage correspond to those for which the device is designed, as shown
in the electrical data label.
AC 230V
1
2
30
AC 110V
1
2
15