User Manual

21
6. - MAINTENANCE
To ensure optimal performance, the unit must be frequently cleaned. Unplug the device
from the mains and let it cool for at least 35 minutes to avoid the risk of burns. Use a vacuum
cleaner or an air compressor and a soft brush or a lens cloth to remove the dust deposited.
The lenses, like any other damaged part, must be replaced with original spare parts.
7. - TECHNICAL SPECIFICATIONS
Power Supply: 100-240V, 50/60HZ
Laser: 1x500mW – Blue Laser
Power conumption: 35W
Operation Mode: Auto, Sound active, Master/slave, DMX512
Electronic Dimming 0-100%
DMX8Channels
Digital display for address and function setting
IR Remote Control
Dimensions (L x H x D): mm.240x90x175
Weight: kg 1,25
240 mm
175 mm
90
mm