System Description

System Description and Installation Manual for MXS ICD10004-01
© Sagetech Corporation 2018 Confidential Proprietary Export-Controlled Page 98 of 160
Report Type and Structure ID
6
5
4
3
0-2
True/Magnetic Heading (HRD)
Vertical Rate Type
(Reserved for) Flight Mode Specific Data
Other (Reserved)
Reserved
Validity Flags
Byte Offset Byte Name Field Description
03
VF0
Bit Data Field(s)
7
6
5
4
3
2
0-1
Capability Codes
Operational Mode
SV Quality - NACp
SV Quality - NACv
SV Quality - SIL
Emergency/Priority Status
Reserved
Validity Flags
These flags indicate whether or not the data contained in the specified field is valid or not. If the bit is set to
“ONE” then the data field contains valid information. If the bit is set to “ZERO” then the data field contains
invalid information.
Participant Address
Byte Offset Byte Name Field Description
04
PA0
PA0 PA1 PA2 Participant Address
05
PA1 0x1C
0x2A
0xA6
0x35
0xB2
0x6A
1CA6B2
2A356A
06
PA2
Participant Address Bytes
Contains the address of the transmitting installation. These fields contain up to 6 hex characters. This can be the
ICAO address or some other type of address.