Built-In Test
BIT1 4
3
2
1
0
Pressure Transducer Ready
FPGA Ready
Rx Oscillator Locked
Tx Oscillator Locked
Mutual Suppression Valid
BIT2
7 (msb)
6
5
4
3
2
1
0
Temperature In Range
Squitter Rate Valid
Transmit Rate In Range
System Latency In Range
Reserved
Reserved
Reserved
Reserved
BIT3
7 (msb)
6
5
4
3
2
1
0
Input Power In Range
ICAO Address Valid
GPS Position Valid
GPS PPS Valid
Reserved
Reserved
Reserved
Reserved
Table 0-3537 Status Response Message Example Data
Message Field Byte Values (original) Byte Message Content
(Hex)
Start Byte AA [ AA ]
Message Type 0x83 Status Response Message [ 83 ]
Message ID An arbitrary number between 0 and 255 (inclusive) that uniquely
identifies the message.
[ 05 ]