System Description
System Description and Installation Manual for MXS ICD10004-01
© Sagetech Corporation 2018 Confidential Proprietary Export-Controlled Page 155 of 160
Step Message Msg
Direction
Field Name
18
Data Values (Hex) Data/Functional Description SDIM
Request Type [ 00 ] Turn on Auto-Output of specified reports for targets
Number of Participants [ 00 20 ] 32 participants
Participant ID [AC 82 EC ] ICAO Address: AC82EC
Requested Reports [ 06 ] Mode Status and Target State reports
Checksum [ C1 ]
9
Receive and decode Acknowledge Message (ACK)
ACK Received
by host
Start Byte [AA] 13.76.3.7
Mess Type [80]
Mess ID [0B]
Packet Len [05]
Ack’d Mess Type [0B] ACK message is returned to indicate that MXS received the Target
Request Message.
System State [00] Extended Squitter fail flag is cleared assuming ADS-B Out Messages
are transmitting at required rates
Pressure Altitude [00 02 77]
Checksum [BE]
10
Receive and decode ADS-B In Report Message. MXS will send ADS-B In reports as ADS-B messages are processed. Processing began when Operating message was
received. ADS-B Reports will continue as long as this Operating Mode is maintained.
ADS-B Received Start Byte [ AA ] 26.4.10.2