System Description
System Description and Installation Manual for MXS ICD10004-01
© Sagetech Corporation 2018 Confidential Proprietary Export-Controlled Page 147 of 160
Step
Message Msg
Direction
FieldName DataValues
(Hex)
Data/FunctionalDescription SDIM
Section
InstallConfiguration[00]
Reserved [0000]
Checksum[4F]
4
If the Installation Response Message indicates a new installation, construct and send Installation Message
15
Installation Sentfrom
Host
StartByte [AA] 13.26.3.
2
MessType [01]
MessID[04]
PacketLen [24]
ICAOAddress[1CA6B2] 1CA6B2
AircraftRegistration: [31323333303231] 1233021
Reserved[0000]
COMPort0 [00] Settodefault38.4kBaud
COMPort1[00] Settodefault38.4kBaud
IPAddress [0A000000] SetIPaddressto10.0.0.1
NetMask [FFFFFF00] SetNetMaskto255.255.255.0
PortNumber [2710] SetPortNumberto10,000
GPSIntegrity[00] GPSIntegrityisunknown
EmitterCategorySet [00] EmitterSetA
EmitterCategory[00] Unknown
AircraftSize [01] Length<=15meters,Width<=23meters
MaxAirspeed[02] 150to300kt
AltitudeEncoderOffset [0000] Zerooffset
Reserved [00 00]
InstallConfiguration [01] Bottomonlyantennainstalled;HostAltitudeResolution=25feet;
HeadingtypeisMagnetic;AirspeedTypeindicated;PressureSensor
HeaterOFF;WOWnotconnected
Reserved[0000]
Checksum [E9]
5 ReceiveanddecodeAcknowledgeMessage(ACK)
ACK Received
byHost
StartByte [AA] 14.26.4.
2
MessType[80]
MessID [04]
PacketLen[05]
Ack’dMessType [01] MXSreceivedtheInstallationMessage.
15
Installation Message data is stored in non-volatile memory and needs to be sent only once.