System Description

System Description and Installation Manual for MXS ICD10004-01
© Sagetech Corporation 2018 Confidential Proprietary Export-Controlled Page 115 of 160
Report Times of Applicability
Byte Offset
Byte Name Field Description
08
RA0
RA1 RA0 Report Times of Applicability
09
RA1 0x00
0x28
0x80
0x60
Time of Applicability: 1.0 seconds
Time of Applicability: 80.75 seconds
Report Times of Applicability
The two bytes of this message (RA0 and RA1) contain the Report Times of Applicability. The data is
formatted such that subfield is in seconds with a resolution of 1/128 seconds. For example, a value of
0x0058 would have a value of 0.6875 seconds.
Selected Altitude Type
Byte Offset
Byte Name Field Description
10
AT0
AT0 Selected Altitude Type
0x00
0x01
0x02-0xFF
Selected altitude derived from Control Panel
Selected altitude derived from Flight Management System (FMS)
Reserved
Selected Altitude Type
Indicates the source of the Selected Altitude data.