System Description
SystemDescriptionandInstallationManualforRangeFinder ICD10000‐01
©SagetechCorporation2018ConfidentialProprietaryExportControlled Page23of130
Table7‐2CommunicationPortSelectMap
SerialBusType/Required
Configuration
MainConnectorInterface
SignalPin
RS‐422Com0
Com0‐Modepin17shouldbeleft
open
Com0‐RX‐ 44
Com0‐RX+ 19
Com0‐TX‐ 45
Com0‐TX+ 20
Com0‐Mode 17
RS‐232Com0
Com0‐Modepin17mustbetied
toground
Com0‐232‐RX 19
Com0‐232‐TX 20
Com0‐Mode 17
RS‐422Com1
Com0‐Modepin43canbeleft
open
Com1‐RX‐ 46
Com1‐RX+ 21
Com1‐TX‐ 47
Com1‐TX+ 22
Com1‐Mode 43
RS‐232Com1
Com1‐Modepin43mustbetied
toground
Com1‐232‐RX 21
Com1‐232‐TX 22
Com1‐Mode 43
Ethernet
Ethernet‐TX+ 23
Ethernet‐RX+ 24
Ethernet‐TX‐ 48
Ethernet‐RX‐ 49