System Description

SystemDescriptionandInstallationManualforRangeFinder ICD1000001
©SagetechCorporation2018ConfidentialProprietaryExportControlled Page115of130
8.5 UseCaseScenarios
UsersinterfacingwiththeRangeFindercanfollowtheseUseCasestoperformcommonoperations.
8.5.1 PowerOn
Uponpowerup,thepoweronBuiltinTestisexecutedandtheStatusResponsemessageissent.TheHostComputerusesthestatusmessage
to assess the state of the Range Finder to determine the next operational state. The following steps outline a typical PowerOn process and
commandsequence.
1. TheWakeupBuiltinTest(BIT)isexecutedoncewhentheRangeFinderispoweredonandpowerisstable.
2. After thepoweronBITisexecuted,theHostshouldsendtheDataRequestMessagetorequesttheStatusResponseMessage.TheHost
shouldthenreviewthe
resultsoftheBITsprovidedintheStatusResponseMessagetoconfirmthattheRangeFinderisOperational.
3. IfRangeFinderisOperational,jumptotheOperationalUseCase(Section8.5.3).
4. IftheStatusMessageindicatesanICAOAddressfailurebutisotherwisefunctional,jumptotheInstallationUse
Case(section8.5.2).
5. IftheStatusMessageindicatesafailure,HostComputershouldlogthefailureand takeappropriateremedialaction.