9.1.3 Clocks
Clock signals must be shielded between two grounds layer and bordered with ground vias.
9.1.4 Data bus and other signals
Data bus and commands have to be routed on the same layer; none of the lines of the bus shall be
parallel to other lines
Lines crossing shall be perpendicular
Suitable other signals track width, thickness.
Data bus must be protected by upper and lower ground plans
9.1.5 Radio
Provide a 50 Ohm micro strip line for antenna connection
9.1.6 Audio
Differential signals have to be routed together, parallel (for example HSET_OUT_P/HSET_OUT_N).
Audio signals have to be isolated, by pair, from all the other signals (ground all around each pair).
Cancel any loops between VBAT and GND next to the speaker to avoid the TDMA burst noise in the
speaker during a communication.
The single-end audio signal should be adopted the same rules as differential signals.
Figure 47: Layout of audio differential signals on a layer n
Figure 48: Adjacent layers of audio differential signals
Layer n-1
Layer n
Layer n+1
GND
HSET_OUT_P
GND
GND
HSET_OUT_P
GND
HSET_OUT_N