User's Manual

page 43/64
Note d’étude / Technical document : URD1– OTL
5665.3
– 003 / 72238 Edition 01
Document Sagemcom Reproduction et divulgation interdites
Sagemcom document. Reproduction and disclosure prohibited
6.5 Recommendations to avoid ESD issues
Insure good ground connections of the HiLoNC V2 module to the customer’s board.
Flex (if any) shall be shielded and FPC connectors shall be correctly grounded at each extremity.
Put capacitor 100nF on battery, or better put varistor or ESD diode in parallel on battery and charger wires
(if any) and on all power wires connected to the module.
Uncouple microphone and speaker by putting capacitor or varistor in parallel of each wire of these
devices.
7. RADIO INTEGRATION
Note that radio engineering competences are mandatory to get accurate radio performance on customer’s
product.
7.1 ANTENNA
A 50 line matching between module and customer’s board, and the RF antenna is required.
Figure 43: Antenna connection
Keep matching circuit on customer’s board but with direct connection in the first step it could be
necessary to make some adjustment later, during RF qualification stage.
The selected antenna must comply with FCC RF exposure limits in GSM850 and PCS1900 band :
GSM850 : MPE < 0.55mW/cm
2
(Distance is 20 cm)
PCS1900 : ERP < 3W