User's Manual
page 26/64
Note d’étude / Technical document : URD1– OTL
5665.3
– 003 / 72238 Edition 01
Document Sagemcom Reproduction et divulgation interdites
Sagemcom document. Reproduction and disclosure prohibited
4.9 GPIO
There are Three GPIOs available on HiloNC V2. All GPIOs have internal pull-up resistors.
GPIOs can directly be controlled with dedicated AT commands.
Thanks to some other special AT commands, GPIOs can for example be used:
• to make an I/O toggling while the module is attached to the network
• to make an I/O toggling when a programmed temperature is reached
• as input to detect the presence of an antenna (with some external additional electronic)
• as input to detect the SIM card presence …etc
4.10 ADC
There is one ADC input pad which can be used to read the value of the voltage applied. Following
characteristics must be met to allow proper performances:
• The input signal voltage must be within 0V and up to 3V
• The input impedance of the pad is 150KΩ
• The input capacitance is typically 10pF.
The AT command AT+KADC will give voltage value with following characteristics:
• 10 bits resolution
• Maximum sampling frequency is 200 KHz.
Consult the AT command Specification document for more information about KADC AT command.
4.11 PCM
There is a master PCM interface available on HiLoNC V2. The PCM interface can be configured by dedicate AT
commands. Following characteristics must be met:
• 16 bits PCM data word length
• Configurable PCM clock rate must not exceed 1MHz
Figure 26: PCM interface timing
4.12 RF BURST INDICATOR
There is one digital output named RF_TX available on HiLoNC V2 to indicate the RF transmission. This output
can not be controlled by AT commands and can not be used for other purpose.
This output can only connect to a transistor but not to drive a LED directly. Otherwise, the RF
transmission will be unexpected affected.