Figure 21: Forbidden area for via and lines
6.4 MECHANICAL SURROUNDING
Avoid any metallic part around the antenna area
Keep jacks, FPCs and battery contact far from antenna area (FLEX)
FPC has to be a shielded one
6.5 OTHER RECOMMENDATIONS – TESTS FOR PRODUCTION/DESIGN
Sagem Communications guarantees the RF performances in conductive mode but strongly recommends
making RF measurements in an anechoic chamber in radiated mode (tests conditions for FTA): the radiated
performances strongly depend on radio integration (layout, antenna, matching circuit, ground area…..)
7. AUDIO INTEGRATION
Audio mandatory tests for FTA are in handset mode only so a particular care must be brought to the design of
audio (mechanical integration, gasket, electronic) in this mode.
The audio norms which describe the audio tests are 3GPP TS 26.131 & 3GPP TS 26.132.
Please note that acoustic competences are mandatory to get accurate audio performance on customer’s
product.
7.1 MECHANICAL INTEGRATION AND ACOUSTICS
Particular care to Handset Mode: FTA