3.5.3 Example 3
Simple boost converter with Linear LT1913 (see LT1316 evaluation kit document).
Figure 11: Example with Linear LT1913
3.6 V24
The HiloNC module features a V24 interface to communicate with the Host through AT commands or for easy
firmware upgrading purpose.
It is recommended to manage an external access to the V24 interface, in order to allow easy software
upgrade (baud rate up to 460.8kbps, validated with ATEN USB/Serial converter).
Pull-up resistors must be connected to DCD, DSR and RI signals if these signals are used.
3.6.1 Complete V24 – connection HiloNC - host
A V24 interface is provided on the 51 pads of the HiloNC module with the following signals: RTS/CTS, RXD/TXD,
DSR, DTR, DCD, RI.