User's Manual
URD1
– OTL 5696.1–
022
/ 72740 Edition 0.4
HILONC-
3GPS
APPLICATION
NOTE
corresponding pins.
·
Metalized plastic is not as effective as metal cans.
·
Shielded
inductors
might
be
needed
on
the
DC/DC
circuits,
or
they
might
need
to
be
placed
in
their
own
shield
area.
8.2.
Example
of
a
customer
board
layout
The following figure is an example of layer allocation for a 6-layer circuit (for reference purposes only):
Depending on
the
customer’s
design
the
layout
could
also
be
done
using
4
layers.
: 6 layer PCB stack
9.
Moisture
sensitivity
level
precautions
According to IPC/JEDEC J-STD 20, the HiLoNC 3GPS has the following MSL level: 3
Customer modules are shipped under a Dry package with all the MSL information labelled.
It
means
that
the
customer’s
factory
must
process
and
solder
the
HiLoNC
3GPS
on
the
customer’s
board
up
to
168
hours
(7
days)
after
the
HiLoNC
3GPS
sealed
package
have
been
opened.
This
duration
is
given
for
factory
floor conditions of T°<30°C, HR 60%.
Note d’étude / Technical document :
01/08/20111
-
Page
30
/
41
Level
Floor
Life
Soak
requirements
Standard
Accelerated
Equivalent
Time
Conditions
Time (hours)
Conditions
Time (hours)
Conditions
3
168
hours
<= 30°C/60% RH
192 +5/-0
30°C / 60% RH
40 +1/-0
60°C / 60%RH