User's Manual
URD1
– OTL 5696.1–
022
/ 72740 Edition 0.4
HILONC-
3GPS
APPLICATION
NOTE
4.4.1.
UART
Interface
To
turn
the
module
off,
use
the
AT
command
AT+CPOF.
If
PWON
is
not
pulled
down
the
module
will
switch
to
OFF
mode
after
the
AT
command,
otherwise
the
module
restarts
immediately
(OFF
sequence
is
performed
followed by power ON sequence).
: Power off sequence for PWON, VGPIO and UART_RTS
4.4.2.
USB
Interface
As
the
module
can
also
be
turned
on
when
a
USB
cable
is
plugged
in,
the
module
turn
off
sequence
requires
the
USB
interface
to
be
OFF
or
VBUS
disconnected
once
the
command
is
sent
and
acknowledged
by
the
module.
Thus,
to
turn
the
module
off
when
USB
interface
is
in
use,
use
the
AT
command
AT+CPOF,
then
disconnect
VBUS
signal
(unplug
the
USB
cable
or
use
a
command
switch
to
switch
off
VBUS)
when
the
module
acknowledges
(responds
with
an
OK
message)
the
command,
otherwise
the
module
will
restart
immediately
(an
OFF sequence is performed followed by a power ON sequence).
4.5.
Sleep
Mode
The AT command AT+KSLEEP allows configuration of the sleep mode.
When AT+KSLEEP=1 has been configured:
·
The
HILONC-3GPS module decides by itself when to enter sleep mode (no tasks running).
·
“0x00”
character
on
serial
link
wakes
up
the
HILONC-3GPS module.
When AT+KSLEEP=0 has been configured:
·
The
HILONC-3GPS module is active when
UART_DSR
signal is active (low electrical level).
·
When
UART_DSR
is
deactivated
(high
electrical
level),
the
HILONC-3GPS
module
enters
sleep
mode
after
a
certain period of time.
·
On
UART_DSR
activation (low electrical level), the HILONC-3GPS module wakes up.
When AT+KSLEEP=2 has been configured:
·
The
HILONC-3GPS module is prevented from ever entering sleep mode.
In
sleep
mode
the
module
reduces
power
consumption
and
waits
for
a
wake
up
signal
from
either
the
network,
Note d’étude / Technical document :
01/08/20111
-
Page
23
/
41