User's Manual

Note d‘étude / Technical document :
URD1 OTL 5696.1 003 / 72361 Edition 02
HILO 3G Application Note
17 January 2011 - Page 34 / 38
8.1.2 Power supplies
Layer for power supply signals (VBAT, VGPIO) is recommended.
Any loop of power signals layout must be avoided on the design.
Suitable power supply (VBAT, VGPIO) track width and thickness.
8.1.3 Clocks
Clock signals must be shielded between two grounds layer and bordered with ground vias.
8.1.4 Data bus and other signals
Data bus and commands have to be routed on the same layer, none of the lines of the bus shall be parallel to other lines
Lines crossing shall be perpendicular
Suitable other signals track width, thickness.
Data bus must be protected by upper and lower ground plans
8.1.5 Radio
Provide a 50 Ohm micro strip line for antenna connection
8.1.6 Audio
Differential signals have to be routed together, parallel (for example HSET_P/HSET_N).
Audio signals have to be isolated, by pair, from all the other signals (ground all around each pair).
Cancel any loops between VBAT and GND next to the speaker to avoid the TDMA burst noise in the speaker during a
communication.
Figure 32: Layout of audio differential signals on a layer n
Figure 33: Adjacent layers of audio differential signals