10.1.3 Clocks
Clock signals must be shielded between two grounds layer and bordered with ground vias.
10.1.4 Data bus and other signals
Data bus must be routed on the same layer with equivalent track length and avoiding long parallel routing.
Lines crossings shall be perpendicular
Suitable signals track width, thickness for other signals.
Data bus must be protected by upper and lower ground plans
10.1.5 Radio
Provide a 50 Ohm micro strip line for antenna connection
For RF matching components do not locate matching inductors too close to shield walls (this may cause
electromagnetic coupling and inductor de-Q).
10.1.6 Audio
Differential signals have to be routed together, parallel (for example HSET_OUT_P/HSET_OUT_N,
MIC_P/MIC_N).
Audio signals have to be isolated, by pair, from all the other signals (ground all around each pair).
Cancel any loops between VBAT and GND next to the speaker to avoid the TDMA burst noise in the
speaker during a communication.
The single-end audio signal should be adopted the same rules as differential signals.
Figure 30: Layout of audio differential signals on a layer n
Figure 31: Adjacent layers of audio differential signals
Layer n-1
Layer n
Layer n+1
GND
HSET_OUT_P
GND
GND
HSET_OUT_P
GND
HSET_OUT_N