Technical information

Proc Sheet 1 01
MyX-4
REMOVING / REPLACING THE ASSEMBLY
FLANGE
1/2
Ref. SCT U33 SM DTS 004– Index A - 29/03/01 Page 5-18
Tools :
- A 0.6mm torx screwdriver
Preliminary operation
1. Remove the back cover ( Proc sheet 0 01).
2. Remove the battery ( Proc sheet 0 02).
3. Remove the front cover ( Proc sheet 0 03).
Removal procedure :
1. Unscrew the six attachment screws on the assembly plate (1)
2. Separate the four stop pins (3) to liberate the assembly flange (2).
Placement procedure :
1. Replace the new assembly flange on its housing.
2. Position and tighten the six attachments screws with torx couple of 0,25 N.m.
Further operations :
1. Replace the front cover (Proc sheet 0 03).
2. Replace the battery (Proc sheet 0 02).
3. Replace the back cover (Proc sheet 0 01).
4. Carry out radio test (Test Sheet 06).