Technical information

Technical Site Documentation – myX-4
Ref. SCT U38 SSC DTS 0022 – Index A - july 30, 200429/03/01 Page 3-18
3.2 LIST OF REPORTED DEFECTS
The following is a list of defects that may be reported :
Code Indicated fault Procedure
A1 No power up Symp Sheet 01
A2 No display up Symp Sheet 04
A3 Freezes up Test Sheet 01
A5 Broken LCD Symp Sheet 04
A6 Line or digit missing Symp Sheet 04
A7 Backlights problem Proc Sheet 1 09 or 3 01
A10 Broken / Missing antenna Proc Sheet 1 09 or 3 01
B1 Defective battery contact Proc Sheet 0 02
B2 Defective mobile charger connector Proc Sheet 1 09 or 3 01
B3 Defective power supply of the board Proc Sheet 1 09 or 3 01
B4 Defective charge icon display Proc Sheet 1 09 or 3 01
B5 Current consumption with phone off Test Sheet 04
B7 Autonomy Symp Sheet 01
B8 Electrically defective battery Test Sheet 03
B9 Mechanical lock problem on battery Proc Sheet 02
B10 Broken battery Test Sheet 03
B11 Defective charger Test Sheet 02
B12 Broken charger Test Sheet 02
B13 Intermittent switch off with reboot Proc Sheet 1 09 or 3 01
B14 Intermittent switch off without reboot Proc Sheet 1 09 or 3 01
C1 Not functioning keyboard Symp Sheet 05
C2 Lateral key problem Symp Sheet 05
D1 Sim missing Proc Sheet 1 09 or 3 01
D2 Other messages Proc Sheet 1 09 or 3 01
D3 EEPROM problem Proc Sheet 1 09 or 3 01
D4 Untuned mobile Proc Sheet 1 09 or 3 01
D5 Hard failure Proc Sheet 1 11 or 3 01
D6 Sim verrou Proc Sheet 1 09 or 3 01
D7 Post code blocked Test Sheet 01
D8 SAV return Proc Sheet 1 09 or 3 01
D9 Unknown battery Test Sheet 03