Technical information
Proc sheet 1 08
myC2-3
5HPRYHDQGSODFHPHWDOGRPH
1/1
2XWLOODJHV
-Tweezers , Gloves , Fixture Metal dome (252254450)
3UHOLPLQDU\RSHUDWLRQ
1. Remove the battery (Proc sheet 0 01).
2. Remove the lower housing of mobile (Proc sheet 1 01).
3. Remove MMI board (Proc sheet 1 07).
5HPRYDOSURFHGXUH
This procedure must be performed by a technician with gloves.
1. Take care of the component metal dome (1) with a tweezers.
2. Put the board upside down (2), take the metal dome (3).
3. Carefully check there is no spot cleft on the board (4).
3ODFHPHQWSURFHGXUH
:DUQLQJ The metal dome is not reusable, it must be replaced by a new metal dome.
1. Position the MMI board in the tool of metal dome (252254450.)
2. Position the metal dome on the MMI board.
3. Take off the board of the tool , put the board upside down and puss part (5)
)XUWKHURSHUDWLRQ
1. Place the keyboard ( Proc sheet 1 04)
2. Place the board MMI (Proc sheet 1 07)
3. Place the lower housing of mobile (Proc sheet 1 01).
4. Place of the battery (Proc sheet 0 01)
Risk of the procédure :
Damage the component of MMI board