User manual

Operation
5-17
Date en cours : 29 juin 2004
D:\CLIENTS\sagem\Pour dossier MFK V2\MFK V2 LU 251597054A MF3760_3780 GB\Utilisation Gb.fm
Operation
Setting your
machine
Getting startedDirectoryMaintenanceSafety ContentsInstallationPrint function
SPECIFIC COPY SETTINGS
When the copy quality is no longer satisfactory, you can perform a calibration. To do so,
reportez-vous au paragraphe Scanner calibration, page 6-17.
Moreover, a high number of controls let you improve the copy quality.
Scanner settings
841 OK - ADVANCED FCT / COPY / RESOLUTION
The Resolution parameter adjusts the photocopying resolution. Select High Speed, Quality
or Photo resolution using keys
or , then validate the choice with the OK key.
842 OK - ADVANCED FCT / COPY / ZOOMING
The zoom setting is used to reduce or enlarge part of the document by choosing the original
and the zoom value to apply to the document, 25 to 400 %. Enter the zoom value required
using the keys of the digital key pad. Validate the choice with the OK key.
843 OK - ADVANCED FCT / COPY / ASSEMBLED
The ASSEMBLED parameter is used to define the choice of your printer outputs; either
assembled or not assembled. Validate the choice with the OK key.
844 OK - ADVANCED FCT / COPY / ORIGIN
If you wish, you can change the origin of the scanner.
By entering new values of X and Y given in mm (X < 210 and Y < 286), you will move the
scanning zone as shown on the figure below.
Select the X and Y coordinates with keys or .
Set the required coordinates with the numeric keypad or or .
Confirm your setting by pressing key OK.
845 OK - ADVANCED FCT / COPY / CONTRAST
The
CONTRAST parameter is used to select the photocopy contrast. Adjust the contrast using
keys
and, then validate the choice with the OK key.
You can also directly adjust the desired contrast using the key, press this key several times until
the required adjustment is obtained without using
845.
scanned area
Top view: scanned side down
y
x
TOP OF SHEET
END OF SHEET